6 Commissioning/Start-up/Shutdown
37 of 92
ILN / ILNC / ILNR
5211.8/08-EN
DANGER
Excessive temperatures due to dry running or excessive gas content in the fluid
handled
Explosion hazard!
Damage to the pump set!
▷
Never operate the pump set without liquid fill.
▷
Prime the pump as per operating instructions. (
▷
Always operate the pump within the permissible operating range.
CAUTION
Abnormal noises, vibrations, temperatures or leakage
Damage to the pump!
▷
Switch off the pump (set) immediately.
▷
Eliminate the causes before returning the pump set to service.
ü
The system piping has been cleaned.
ü
The pump, suction line and inlet tank (if any) have been vented and primed with
the fluid to be handled.
ü
The lines for priming and venting have been closed.
ü
The coupling has been aligned, and the alignment has been checked.
(
CAUTION
Start-up against open discharge line
Motor overload!
▷
Make sure the motor has sufficient power reserves.
▷
Use a soft starter.
▷
Use speed control.
1. Fully open the shut-off element in the suction head line / suction lift line.
2. Close or slightly open the shut-off element in the discharge line.
3. Start up the motor.
4. Immediately after the pump has reached full rotational speed, slowly open the
shut-off element in the discharge line and adjust it to comply with the duty
point.
DANGER
Seal leakages at operating temperature
Leakage of hot or toxic fluid handled!
▷
Once the operating temperature has been reached, re-tighten the hexagon
socket head cap screws between casing and casing cover.