5 Installation/Commissioning
23 of 40
KSB Guard
5.3 Assigning and setting up
NOTE
The sensor unit must be initially assigned to a pump set.
This assignment cannot be subsequently undone and remains valid for the service
life of the sensor unit.
Correct assignment is key to ensuring proper functionality of the device.
Measurement data can only be saved after the assignment has been made.
You can make the assignment on the KSB Guard Web Portal (
) or
in the KSB Guard app (available for iOS and Android).
Further data will be required as you continue setting up the KSB Guard app. We
recommend that you collect the data in advance so that it is readily available when
you need it. The following data is required:
Table 10:
Data required to register the pump set in the KSB Guard app
Required data
Example
Notes
Serial number of the sensor unit
(
GS118W220071
Designation of the pump set
Pump 123
Location of the pump set
Hall 2
Functional location of the pump set
B2411
Optional:
Photo of the pump set/pump
Data from the pump name plate
Manufacturer
KSB
Year of construction
2018
Serial number
4)
997123456700010000
Type series
Etanorm
Size
050-032-161
Nominal head
25 m
Nominal flow rate
50 m³/h
Nominal speed
1450 rpm
Number of stages
1
Operating hours of the pump set to date (initial
value for the operating hours counter)
1000 h
Data from the motor name plate
Nominal power
15 kW
Nominal speed
1450 rpm
Power factor (cos
ϕ
)
0,86
Other details
Variable speed system (yes or no)
No
Application of the pump
Heat supply system
Fluid temperature
+20 °C to +30 °C
Density of the fluid handled
997 kg/m³
Bearing type and, if applicable, operating hours
since most recent bearing lubrication/
replacement
Grease, re-lubrication, 1000 h
4)
With a pump set from KSB, data on the pump can be accessed when necessary. To do this, it is important that you enter the
KSB serial number in the corresponding field of the app/ web portal. If data is available, it is also displayed in the app or on
the web portal and must be checked to ensure that it is accurate and up to date.
Содержание Guard
Страница 1: ...KSB Guard Installation Operating Manual ...
Страница 4: ...Contents 4 of 40 KSB Guard 11 EU Declaration of Conformity 35 Index 36 ...
Страница 26: ...6 Operation 26 of 40 KSB Guard The device then automatically switches to stand by mode and all LEDs extinguish ...
Страница 38: ......
Страница 39: ......
Страница 40: ...KSB SE Co KGaA Johann Klein Straße 9 67227 Frankenthal Germany Tel 49 6233 86 0 www ksb com 4079 8 01 EN ...