5 Installation/Commissioning
20 of 40
KSB Guard
5.1.3 Establishing a connection between the sensor unit and the transmission and
battery unit
NOTE
The adhesive bond between the sensor unit and bearing bracket or drive lantern
must be sufficiently cured before continuing to install the connecting cable to avoid
changing the position of the sensor unit.
1. Connect the connecting cable of the sensor unit to the transmission and battery
unit.
5.1.4 Commissioning
Supplied condition
The transmission and battery unit is delivered in
Deep Sleep
mode
Section 6.1, Page 25) . This operating mode remains active until commissioning
has been completed successfully.
During commissioning, a sensor unit must be detected and a functioning gateway
found within wireless range.
If commissioning is not successful, the device remains in
Deep Sleep
mode until it is
woken up by pressing and holding down the relevant button.
Commissioning
1
2
5
6
3
4
Fig. 10:
Transmission and battery unit
1
Pushbutton
2
Status LED A
3
Status LED B
4
Level LEDs for indicating the signal
strength of the gateway connection
5
Cover for housing screws
6
Connection for connecting cable to
sensor unit
ü
The gateway has been installed and the signal strength indicated is sufficient.
ü
The sensor has been fitted at a suitable location on the pump set.
ü
The sensor unit and the transmission and battery unit are interconnected and the
power cable has been connected.
1. Press and hold the pushbutton (1) on the transmission and battery unit for 3
seconds. Release the pushbutton as soon as status LEDs A and B of the
transmission and battery unit briefly light up simultaneously.
ð
All LEDs of the transmission and battery unit flash in a predefined sequence and
extinguish. The device is now in stand-by mode and commissioning/ start-up was
successful.
ð
Commissioning/ start-up must be repeated if the LEDs of the transmission and
battery unit do not light up after a brief waiting period.
Содержание Guard
Страница 1: ...KSB Guard Installation Operating Manual ...
Страница 4: ...Contents 4 of 40 KSB Guard 11 EU Declaration of Conformity 35 Index 36 ...
Страница 26: ...6 Operation 26 of 40 KSB Guard The device then automatically switches to stand by mode and all LEDs extinguish ...
Страница 38: ......
Страница 39: ......
Страница 40: ...KSB SE Co KGaA Johann Klein Straße 9 67227 Frankenthal Germany Tel 49 6233 86 0 www ksb com 4079 8 01 EN ...