background image

Exploded view and list of components

(160)

1x412.01

(745)

(745.01)

2x(412.02)

(101)

4X(563)

160

745

101

4x(563)

(89-12)

433

(230)

1x(412.03)

(331)

1x(412.04)

(420)

230

171

173

(81-22)

(525)

(81.59)

(832)

(831)

831

(81-22)

(833)

4x(900.01)

F iltra N 22; 24; 30

Filtra N  6; 8; 12; 14; 18

5x(900.1)

837

(833)

4x(563)

1x(412.04)

(81-23)

4x(900.02)

  (81.93)

 

    (837)

 

 4x(900)

 

    (331)

 

     833

 

81-59

(81-59)

  (81-93)

 

    (837)

 

  4x(900)

 

    (331)

 

    (525)

 

     833

81-59

321 (321)

 

(931)

 (931)

818

(321)

(932)

(818)

1x(412.01)

837

 (837)

833

833

4x(900.02)

99.9.01

1x(412.01)  2x(412.02) 1x(412.03) 1x(412.04) 2x(912.1)

(837)

2x(912.01)

(832)

(831)

831

99.9.02

5x(412.01)  

(81-23)

171

173

Exploded view

List of components

Part No.

Description

Part No.

Description

101

Pump casing

81-23

Support foot

160

Cover

81-59

Stator

171

Diffuser

81-93

Protective switch

173

Diffuser wall

818

Rotor

230

Impeller

831

Fan impeller

321

Radial ball bearing

833

Terminal box

412.01

Bonnet gasket

837

Capacitor

433

Mechanical seal

99-9

Sealing elements and screws

745

Filter basket

 

 

Domestic water supply / swimming pools

Recirculating pump for swimming pool filtering systems

 

 
 

Filtra N

7

Содержание Filtra N

Страница 1: ...Recirculation Pump for Swimming Pool Filter Systems Filtra N Type Series Booklet...

Страница 2: ...rovided herein must neither be distributed copied reproduced edi ted or processed for any other purpose nor otherwise transmitted published or made available to a third party without KSB s express wri...

Страница 3: ...ems 4 Filtra N 4 Main applications 4 Fluids handled 4 Operating data 4 Designation 4 Design details 4 Materials 4 Product benefits 4 Technical data 5 Characteristic curves 5 Filtra N 6 8 12 14 18 22 2...

Страница 4: ...ged open in the mid dle to facilitate cleaning Drive 230 V single phase a c motor protected by a temperature switch with automatic reset Three phase motor 230 400 V Surface cooled Enclosure IP 44 Ther...

Страница 5: ...57 9 2 8 D 0 60 0 40 2 1 1 2 39300058 9 2 12 D 0 70 0 40 2 3 1 3 39300059 9 2 14 D 0 90 0 70 3 1 1 8 39300060 11 18 D 1 00 0 70 3 5 2 0 39300061 11 22 D 1 40 1 10 5 0 2 9 39300062 13 3 24 D 1 60 1 10...

Страница 6: ...12 14 18 512 5 22 24 30 534 Scope of supply Depending on the model the following items are included in the scope of supply Pump set Accessories Required accessories can be purchased from our distribu...

Страница 7: ...837 833 833 4x 900 02 99 9 01 1x 412 01 2x 412 02 1x 412 03 1x 412 04 2x 912 1 837 2x 912 01 832 831 831 99 9 02 5x 412 01 81 23 171 173 Exploded view List of components Part No Description Part No De...

Страница 8: ...2127 5 03 EN 22 10 2012 KSB Aktiengesellschaft 67225 Frankenthal Johann Klein Str 9 67227 Frankenthal Germany Tel 49 6233 86 0 Fax 49 6233 86 3401 www ksb com...

Отзывы: