5 Installation at Site
26 of 76
Etaprime L
Size
Suction nozzle
Discharge nozzle
DN
[mm]
Fx
Fy
Fz
∑
F
Mx
My
Mz
DN
Fx
Fy
Fz
∑
F
Mx
My
Mz
[N]
[N]
[N]
[N]
[Nm]
[Nm]
[Nm] [mm]
[N]
[N]
[N]
[N]
[Nm]
[Nm]
[Nm]
50-50-130
50
1240 1010
830
1802
650
320
500
50
1010
830
1240 1802
650
320
500
50-50-160
50
1240 1010
830
1802
650
320
500
50
1010
830
1240 1802
650
320
500
65-65-150
65
1600 1300 1050 2314
1050
550
780
65
1300 1050 1600 2314
1050
550
780
65-65-180
65
1600 1300 1050 2314
1050
550
780
65
1300 1050 1600 2314
1050
550
780
80-80-170
80
2000 1550 1300 2845
1330
690
1010
80
1550 1300 2000 2845
1330
690
1010
80-80-200
80
2000 1550 1300 2845
1330
690
1010
80
1550 1300 2000 2845
1330
690
1010
5.4.3 Auxiliary connections
DANGER
Risk of potentially explosive atmosphere by mixing of incompatible fluids in the
auxiliary piping
Risk of burns!
Explosion hazard!
▷
Make sure that the barrier fluid or quench liquid are compatible with the fluid
handled.
WARNING
Failure to use or incorrect use of auxiliary connections (e.g. barrier fluid, flushing
liquid, etc.)
Risk of injury from escaping fluid!
Risk of burns!
Malfunction of the pump!
▷
Refer to the general arrangement drawing, the piping layout and pump
markings (if any) for the quantity, dimensions and locations of auxiliary
connections.
▷
Use the auxiliary connections provided.
5.5 Enclosure/insulation
DANGER
Risk of potentially explosive atmosphere due to insufficient venting
Explosion hazard!
▷
Make sure the space between the casing cover/discharge cover and the bearing
cover is sufficiently vented.
▷
Never close or cover the perforation of the bearing bracket guards (e.g. by
insulation).
WARNING
The volute casing and casing/discharge cover take on the same temperature as
the fluid handled
Risk of burns!
▷
Insulate the volute casing.
▷
Fit protective equipment.
Содержание Etaprime L
Страница 1: ...Self priming Pump Etaprime L Installation Operating Manual...
Страница 74: ......
Страница 75: ......