7 Servicing/Maintenance
36 of 62
Etanorm FXV
1311.83/06-EN
If required, the bearings may be lubricated with greases of other soap bases.
Make sure to remove any old grease and rinse the bearings thoroughly.
7.2.3.1.3 Grease quantity
Table 12:
Grease quantity per grease-lubricated DIN 625 radial ball bearing
Size
Code
Grease quantity per
bearing
[g]
065-040-250
6305 2Z C3
5
065-040-315
6310 2Z C3
12
065-050-250
6305 2Z C3
5
065-050-200
6305 2Z C3
5
065-050-315
6310 2Z C3
12
080-065-200
6305 2Z C3
5
080-065-250
6307 2Z C3
10
080-065-315
6312 2Z C3
20
100-080-200
6307 2Z C3
10
100-080-250
6307 2Z C3
10
100-080-315
6312 2Z C3
20
125-100-315
6312 2Z C3
20
125-100-200
6307 Z C3
10
150-125-250
6312 2Z C3
10
150-125-315
6311 2Z C3
15
200-150-400
6311 2Z C3
15
250-150-400
6312 2Z C3
20
7.2.3.1.4 Changing the grease
CAUTION
Mixing greases of differing soap bases
Changed lubricating qualities!
▷
Thoroughly clean the bearings.
▷
Adjust the re-lubrication intervals to the grease used.
ü
The pump has been dismantled for changing the grease.
1. Remove the outer cover plate of each bearing with a suitable tool. Dispose of
the cover plates.
2. Only half-fill the bearing cavities with grease.
Continue using the bearings without the outer cover plates (variant Z C3).