DANGER
Insufficient preparation of work on the pump (set)
Risk of injury!
▷
Properly shut down the pump set.
▷
Close the shut-off elements in suction and discharge line.
▷
Drain the pump and release the pump pressure.
▷
Close any auxiliary connections.
▷
Allow the pump set to cool down to ambient temperature.
NOTE
After a prolonged period of operation the individual components may be hard to
pull off the shaft. If this is the case, use a brand name penetrating agent and/or - if
possible - an appropriate puller.
7.4.2 Preparing the pump set
1.
Interrupt the power supply and secure the pump against unintentional start-up.
2.
Disconnect and remove all auxiliary pipework.
3.
Remove the coupling guard.
4.
Remove the coupling spacer, if any.
7.4.3 Dismantling the motor
NOTE
On pump sets with spacer-type couplings, the back pull-out unit can be removed
while the motor remains bolted to the baseplate.
WARNING
Motor tipping over
Risk of crushing hands and feet!
▷
Suspend or support the motor to prevent it from tipping over.
1.
Disconnect the motor from the power supply.
2.
Unbolt the motor from the baseplate.
3.
Shift the motor to separate it from the pump.
7.4.4 Removing the back pull-out unit
✓
The notes and steps stated in
have been observed/carried out.
✓
On pump sets without spacer-type coupling, the motor has been removed.
WARNING
Back pull-out unit tipping over
Risk of crushing hands and feet!
▷
Suspend or support the bearing bracket at the pump end.
1.
If required, suspend or support bearing bracket 330 to prevent it from tipping
over.
2.
Unbolt support foot 183 from the baseplate.
3.
Undo hexagon nut 920.1 and hexagon head bolt 901.1 at the pump casing.
7 Servicing/Maintenance
Etachrom NC
43 of 62