5 Installation at Site
26 of 70
Etachrom L
1212.8/19-EN
CAUTION
Aggressive flushing liquid and pickling agent
Damage to the pump!
▷
Match the cleaning operation mode and duration of flushing and pickling to
the casing materials and seal materials used.
5.3.2 Permissible forces and moments at the pump nozzles
F
V
F
Vmax
2
F
H
F
Hmax
2
M
tmax
M
t
2
+
+
- 1
F
V
F
H
F
H
F
V
F
H
F
H
Fig. 10:
Forces and moments at the pump nozzles
The following condition must be met:
∑IF
V
I, ∑IF
H
I, and ∑IM
t
I are the sums of the absolute values of the respective loads
acting on the nozzles. Neither the load direction nor the load distribution among the
nozzles are taken into account in these sums.
Table 8:
Forces and moments at the pump nozzles
5)
Size
F
Vmax
F
Hmax
M
tmax
[kN]
[kN]
[kNm]
050-025-125.1
2,6
1,8
0,55
050-025-125
2,6
1,8
0,55
050-025-160
2,5
1,7
0,5
050-025-200
2,5
1,7
0,5
050-025-250
2,5
1,7
0,5
050-032-125.1
2,6
1,8
0,55
050-032-125
2,6
1,8
0,55
050-032-160
2,5
1,7
0,5
050-032-200
2,5
1,7
0,5
050-032-250
2,5
1,7
0,5
065-040-125
2,6
1,8
0,6
065-040-160
2,6
1,8
0,6
065-040-200
2,6
1,8
0,6
065-040-250
2,6
1,8
0,6
065-050-125
2,7
2,0
0,75
065-050-160
2,7
1,9
0,7
065-050-200
2,7
1,9
0,7
065-050-250
2,7
1,9
0,7
080-065-200
3,0
2,2
0,85
080-065-250
3,2
2,4
1,05
5
The indicated values apply to pumps made of chrome nickel molybdenum steel 1.4571 on non-grouted
baseplates.