7 Servicing/Maintenance
28 of 38
ECOLINE GT 40
7367.8/06-EN
3. If leakage occurs, tighten the nuts at the gland follower until leakage stops.
4. Reduce the pressure for seat tightness testing.
7.2.4.4 Fitting the bonnet/cover gasket
ü
The spare parts required are available.
ü
All dismantled parts have been cleaned and checked for wear.
ü
Any damaged or worn parts have been replaced by original spare parts.
1. Insert a new joint ring 411 into the groove.
2. Fit the bonnet with the valve trim.
3. Tighten bonnet/cover nuts 920.3 crosswise to the specified tightening torque
7.3 Tightening torques
Table 7:
Bolt tightening torques [kg/m]
Metric size
Material
Inch
Metric
B7/B16/&L7
B8/B8M
5-16 - 18 UNC
M8 x 1,25
2,0
2,0
3/8 - 16 UNC
M10 x 1,5
2,8
2,8
7/16 - 14 UNC
-
4,2
4,2
1/2 - 13 UNC
M12 x 1,75
7,0
6,3
9/16 - 12 UNC
-
9,7
8,6
5/8 - 11 UNC
M16 x 2
13,2
11,8
3/4 - 10 UNC
M20 x 2,5
23,6
20,8
7/8 - 9 UNC
M22 x 2,5
37,5
33,3
1 - 8 UNC
M24 x 3
56,8
49,9
1 - 1/8 - 8 UN
M30 x 3,5
83,2
74,2
1 - 1/4 - 7 UN
M33 x 3,5
117,2
104,0
1 - 3/8 - 8 UN
M36 x 4
159,4
141,4
1 - 1/2 - 8 UN
M39 x 4
210,6
187,1
1 - 5/8 - 8 UN
M42 x 4,5
270,9
241,1
1 - 3/4 - 8 UN
M45 x 4,5
342,9
304,8
1 - 7/8 - 8 UN
M48 x 5
425,1
379,0
2 - 8 UN
M50 x 1,5
521,7
463,5
2 - 1/8 - 8 UN
-
623,5
560,5
2 - 1/4 - 8 UN
M56 x 5,5
753,7
669,9
2 - 1/2 - 8 UN
M64 x 5
1045,4
929,7
Содержание ECOLINE GT 40
Страница 1: ...Gate Valve ECOLINE GT 40 Operating Manual...
Страница 36: ......
Страница 37: ......
Страница 38: ...KSB SE Co KGaA Johann Klein Stra e 9 67227 Frankenthal Germany Tel 49 6233 86 0 www ksb com 7367 8 06 EN...