8 Trouble-shooting
99 of 116
CHTRa
8 Trouble-shooting
WARNING
Improper work to remedy faults
Risk of injury!
▷
For any work performed to remedy faults, observe the relevant information
given in this operating manual and/or in the product literature provided by the
accessories manufacturer.
If problems occur that are not described in the following table, consultation with the
KSB customer service is required.
A
Pump overheats and seizes
B
Bearings have short life
C
Pump vibrates and causes running noises
D
Mechanical seal has short life
E
Mechanical seal leaks excessively
F
Pump requires excessive power
G
Pump looses initial fill after start-up
H
Insufficient pressure delivered
I
Insufficient flow rate delivered
J
Pump is running, but does not pump
Table 21:
Trouble-shooting of system faults
A B C D E
F
G H I
J
Possible cause
Remedy
✘
-
-
-
-
-
-
-
-
✘
Pump not primed.
Vent and prime pump and/or pipes.
-
-
✘
-
-
-
✘
-
✘ ✘
Pump or suction line not completely
filled with fluid.
-
-
✘
-
-
-
✘
-
✘ ✘
Suction lift too high or fluid level too
low.
NPSH
a>
NPSH
r
Check for sufficient submergence.
Check installed strainers and valves,
remove any dirt.
✘
-
✘
-
-
-
-
-
✘ ✘
Insufficient margin between suction
pressure and vapour pressure
-
-
-
-
-
-
✘ ✘ ✘
- Excessive amount of air or gas in fluid
handled
Check system and/or pipes and vent.
-
-
-
-
-
-
✘
-
✘ ✘
Air pocket or vapour pocket in suction
line
Check the suction line’s layout to rule
out the formation of any vapour
pockets; correct suction line layout if
necessary.
-
-
-
-
-
-
✘
-
✘
- Air leaks into suction line.
Check suction line is airtight.
-
-
-
-
-
-
✘
-
✘
- Air leaks into pump through mechanical
seal, sleeve joints, pipe joints or plugs.
Check parts for damage and replace if
necessary.
Contact KSB.
-
-
✘
-
-
-
✘
-
✘ ✘
Inflow rate too small.
Check system design.
-
-
-
-
-
-
-
✘ ✘ ✘
Speed too low.
Contact KSB.
-
-
-
-
-
✘
-
-
-
- Speed too high.
Contact KSB.
-
-
-
-
-
-
-
✘ ✘ ✘
Total head of system higher than
differential head of pump
Check system losses.
Remedy or contact KSB.
-
-
-
-
-
✘
-
-
-
- Total head of system lower than pump
design head
-
-
-
-
-
✘
-
-
-
- Specific gravity of fluid different from
design
Check.
Contact KSB.
-
-
-
-
-
✘
-
✘ ✘
- Viscosity of fluid differs from viscosity
designed for
Содержание CHTRa
Страница 1: ...Process Pump CHTRa Installation Operating Manual...
Страница 112: ...10 Related Documents 112 of 116 CHTRa 10 5 Order specific documents...
Страница 114: ...Index 114 of 116 CHTRa W Warnings 9 Warranty claims 7 Weight 110...
Страница 115: ......
Страница 116: ...KSB SE Co KGaA Johann Klein Stra e 9 67227 Frankenthal Germany Tel 49 6233 86 0 www ksb com 2700 81 03 EN...