7 Servicing/Maintenance
74 of 116
CHTRa
A regular maintenance schedule will help avoid expensive repairs and contribute to
trouble-free, reliable operation of the pump, pump set and pump parts with a
minimum of servicing/maintenance expenditure and work.
NOTE
All maintenance work, service work and installation work can be carried out by KSB
Service or authorised workshops. For contact details please refer to the enclosed
"Addresses" booklet or visit "
Never use force when dismantling and reassembling the pump set.
7.1.1 Supervision plan
This supervision plan contains the minimum scope of work recommended by KSB. Do
not exceed the time intervals indicated; shorter intervals serve to improve the
operating reliability.
Table 18:
Supervision plan
What/where
How
Value to be met
Interval
Radial plain bearing
Tilting-pad thrust bearing
Radial rolling element
bearing
Rolling element thrust
bearing
Check the temperature.
5)
Weekly
Check the oil level
(only designs with oil ring
lubrication).
Middle between the
minimum and maximum
marks
Weekly
Check smooth running.
The pump must run quietly
and free from vibrations.
Weekly
Mechanical seal
Check for leakage.
5)
Or see manufacturer's
product literature
5)
Or see manufacturer's
product literature
Mechanical seal/
Temperature measurement
(if applicable)
Check the temperature.
5)
Or see manufacturer's
product literature
5)
Or see manufacturer's
product literature
Differential pressure meter,
strainer - inlet pipe
(if applicable)
Check the differential
pressure.
5)
Weekly
Differential pressure meter,
duplex filter
(if applicable)
Check the differential
pressure.
5)
Weekly
Measuring instrument,
suction side p
s
(instrument
holer)
(if applicable)
Check the pressure.
5)
Weekly
Measuring instrument,
discharge side p
d
(instrument
holer)
(if applicable)
Check the pressure.
5)
Weekly
Measuring instrument,
tapping (instrument holder)
(if applicable)
Check the pressure.
5)
Weekly
Measuring instrument,
balancing water p
E
(instrument holer)
(if applicable)
Check the pressure.
5)
Weekly
Thermometer (suction/
discharge nozzle)
(if applicable)
Check the temperature.
5)
Weekly
5)
See list of measuring points, interlock criteria or manufacturer’s product literature
Содержание CHTRa
Страница 1: ...Process Pump CHTRa Installation Operating Manual...
Страница 112: ...10 Related Documents 112 of 116 CHTRa 10 5 Order specific documents...
Страница 114: ...Index 114 of 116 CHTRa W Warnings 9 Warranty claims 7 Weight 110...
Страница 115: ......
Страница 116: ...KSB SE Co KGaA Johann Klein Stra e 9 67227 Frankenthal Germany Tel 49 6233 86 0 www ksb com 2700 81 03 EN...