5 Installation at Site
42 of 116
CHTRa
Fig. 23:
Fitting a strainer/filter
A
Inlet line
B
Suction line, pump
C
Connection, differential pressure
monitoring
D
Strainer housing
H
approx. 300 mm
5.16.5 Minimum flow system
Minimum flow system
1. Arrange the minimum flow system (if applicable) as shown on the P + I diagram.
2. Perform the installation as described in the manufacturer’s product literature.
Minimum flow valve
1. Fit the minimum flow valve (if applicable) to the pump’s discharge nozzle as
stated in the manufacturer’s product literature.
5.16.6 Connecting the piping
DANGER
Impermissible loads acting on the pump nozzles
Danger to life from escaping hot, toxic, corrosive or flammable fluids!
▷
Do not use the pump as an anchorage point for the piping.
▷
Anchor the pipes in close proximity to the pump and connect them properly
without transmitting any stresses or strains.
▷
Observe the permissible forces and moments at the pump nozzles.
▷
Take appropriate measures to compensate for thermal expansion of the piping.
CAUTION
Incorrect earthing during welding work at the piping
Destruction of rolling element bearings (pitting effect)!
▷
Never earth the electric welding equipment on the pump or baseplate.
▷
Prevent current flowing through the rolling element bearings.
Содержание CHTRa
Страница 1: ...Process Pump CHTRa Installation Operating Manual...
Страница 112: ...10 Related Documents 112 of 116 CHTRa 10 5 Order specific documents...
Страница 114: ...Index 114 of 116 CHTRa W Warnings 9 Warranty claims 7 Weight 110...
Страница 115: ......
Страница 116: ...KSB SE Co KGaA Johann Klein Stra e 9 67227 Frankenthal Germany Tel 49 6233 86 0 www ksb com 2700 81 03 EN...