CAUTION
Lubricant level too high
Mechanical seal operation is impaired!
▷
Always place the submersible mixer in horizontal position (as shown) for filling
in the lubricant.
903.01
411.01
Lubricant filler plug
on gear unit
Lubricant check plug
on gear unit
Fig. 12: Filling in lubricant (propeller not shown)
✓
The submersible mixer is positioned as shown.
1. Undo screw plug 903.01 and joint ring 411.01.
2. Fill the lubricant through the lubricant filler opening until the lubricant reservoir
overflows.
3. Close screw plug 903.01 again, fitting a new joint ring 411.01.
4. Unscrew the lubricant check plug on the gear unit.
5. Unscrew the lubricant filler plug on the gear unit.
6. Fill the lubricant through the lubricant filler opening into the lubricant chamber
until the lubricant flows out of the lubricant check opening.
7. Screw the lubricant filler plug of the gear unit back in.
7 Servicing/Maintenance
36 of 60
Amaprop®
Goodnal STP ST041 Biological Treatment (KSB Amaprop Installation and Operating Manual) Vendor Manual
Q-Pulse Id VM386
Active 29/10/2013