5 Installation at Site
44 of 126
Amacan K
1579.807/07-EN
DANGER
Connection of damaged electric cables
Danger of death from electric shock!
▷
Check the electric cables for any damage before connecting them.
▷
Never connect damaged electric cables.
▷
Replace damaged electric cables.
CAUTION
Flow-induced motion
Damage to the power cable!
▷
Run the power cable upwards without slack.
Fig. 26:
Fastening the power cables
1. Run the power cables upwards without slack and fasten them.
2. Only remove the protective caps from the power cables immediately before
connecting the cables.
3. If necessary, adjust the length of the power cables to the site requirements.
4. After shortening the cables, correctly re-affix the markings on the individual
conductors at the cable ends.
Terminal for the potential
equalisation conductor
The pump set is not fitted with an external potential equalisation connection (risk of
corrosion).
DANGER
Incorrect wiring
Explosion hazard!
▷
Explosion-proof pump sets installed in a tank must never be retrofitted with an
external potential equalisation connection!
DANGER
Touching the pump set during operation
Electric shock!
▷
Make sure that the pump set cannot be touched during operation.