9 Trouble-shooting
39 of 56
Ama-Drainer 80/100
2331.823/07-EN
9 Trouble-shooting
WARNING
Improper work to remedy faults
Risk of injury!
▷
For any work performed to remedy faults, observe the relevant information
given in this instruction manual and/or in the product literature provided by the
accessories manufacturer.
NOTE
Please contact KSB Service before carrying out any work on the pump's internal
parts during the warranty period. Non-compliance will lead to forfeiture of
warranty cover and of any and all rights to claims for damages.
If problems occur that are not described in the following table, consultation with the
KSB service is required.
A
Pump is running, but does not deliver
B
Insufficient flow rate
C
Excessive current/power input
D
Insufficient discharge head
E
Vibrations and noise during pump operation
Table 11:
Trouble-shooting
A B C D E Possible causes
Remedy
7)
-
✘
-
-
- Pump delivers against an excessively high
pressure.
Fully open the gate valve.
-
✘
-
-
- Gate valve in the discharge line is not fully
open.
Fully open the gate valve.
-
-
✘
-
✘
Pump running in off-design conditions (low
flow / overload)
Check the pump's operating data.
✘
-
-
-
- Pump or piping are not completely vented.
Clean vent bore E in duckfoot bend P3.
✘
-
-
-
- Pump intake clogged by deposits
Clean the intake, pump components and lift check
valve.
-
✘
-
✘ ✘
Supply line or impeller clogged
Remove deposits in the pump and/or piping.
-
-
✘
-
✘
Dirt/fibres in the clearance between the
casing wall and impeller of a sluggish rotor.
Check whether the impeller can be easily rotated;
clean the hydraulic system, if required.
-
✘ ✘ ✘ ✘
Wear of internal components
Replace worn components by new ones.
✘ ✘
-
✘
- Defective riser (pipe and sealing element)
Replace defective riser pipe and sealing elements.
-
✘
-
✘ ✘
Impermissible air or gas content in the fluid
handled
Contact KSB.
-
✘ ✘ ✘ ✘
Wrong direction of rotation
If the pump set is running in the wrong direction
of rotation, check the electrical connection and the
control system, if necessary.
-
-
✘
-
- Operating voltage is too low.
Check mains voltage.
Check cable connections.
✘
-
-
-
- Motor is not running because of lack of
voltage.
Check electrical installation, inform electric utility
company.
✘ ✘
-
✘
- Motor is running on 2 phases only.
Replace defective fuse. Check cable connections.
✘
-
-
-
- Motor winding or electric cable are defective. Contact KSB's pump service.
-
-
✘
-
✘
Defective radial bearing in the motor.
Contact KSB.
7)
The pump pressure must be released before attempting to remedy faults on parts which are subjected to pressure.
Disconnect the pump from the power supply and let it cool down before working on it.
Содержание Ama-Drainer 80
Страница 1: ...Submersible Waste Water Pump Ama Drainer 80 100 Installation Operating Manual ...
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ...KSB SE Co KGaA Johann Klein Straße 9 67227 Frankenthal Germany Tel 49 6233 86 0 www ksb com 2331 823 07 EN ...