sETTINGs ADJusTMENT

sETTINGs ADJusTMENT

Adjusting the settings with the remote control

If necessary, the sensor settings can be adjusted as following:
shut off the water supply. In order to adjust the sensor with the remote control, hold the 

remote control straight in front of the sensor in a distance of about 6-8” (15-20cm). choose 

the function you want to adjust by pressing once on one of the function buttons. after 

pressing once on a specific function button, a quick flashing of the led at the front of the 

sensor will occur. at this stage, you can change the setting by pressing the (+) or the (-) 

buttons, every push will increase or decrease one level. after finishing the adjustment, turn 

the water supply back on. 

delaY  out tIme: this button allows modifying the flushing start time after 

the user moves away from the product. a delay out time close to 0 will save 

more water. an increased delay out time will make the user experience more 

comfortable.  
If required, the delay out time can be modified as follows:

Press the out button. wait until a quick flashing of the led in the sensor eye 

is perceived. then, press + to increase the delay out time and – to reduce it.

temPorarY off functIon: this function is ideal to perform any kind of 

activity in front of the sensor without operating the system (for example, 

cleaning). 
the product will remain shut for 1 minute when this button is pressed once. 

to cancel this function and to return to normal operation press the on/off 

button again or wait 1 minute.

reset Button: this function restores all the factory settings except for the 

sensor range. If required, press the reset button and without releasing it, 

press the + button once.

securItY tIme: the security time, prevents continuous flushing of water 

due to reflections or vandalism. By default, if the sensor is covered for more 

than 90 seconds the water flow will shut automatically. to resume regular 

operation any obstruction must be removed.
Press the sec button. wait until a quick flashing of the led of the sensor eye 

is perceived. then, press + to increase the security time and – to reduce it.

24 Hour HYgIene flusH: this model includes a 24 hours hygiene flush 

which is disabled. to activate the hygiene flush, press the clock button. wait 

until a quick flashing of the led in the sensor eye is perceived. then press + 

to activate the hygiene flush. to disable it again, press – to deactivate it.

comfort flusH: If your model includes a comfort flusH setting, it can 

be activated by pressing the flush button. 
when the button is pressed, one blink of the led in the sensor eye is 

perceived. the pre-programmed flush cycle will take place then.
the comfort flush cannot be interrupted or deactivated by pressing any 

button until it is over.

detectIon range: only if necessary, use the remote control to adjust the 

sensor range as follows:
Press the range button. wait until a quick flashing of the led in the sensor 

eye is perceived. then, press + to increase the one level and – to reduce it 

every push will increase or decrease one level.

note: once you have changed the detection range with the remote control, this 

distance will be remembered by the sensor, even if the power source is disconnected.

delaY  In tIme:  If required, the delay in time can also be modified as follows: 

Press the In button. wait until a quick flashing of the led in the sensor eye is 

perceived. then, press + to increase the delay in time and – to reduce it.

detectIon 

range 

delaY  In tIme

securItY tIme 

comfort flusH

delaY  out tIme 

temPorarY off 

functIon 

reset

HYgIene flusH

Содержание THERMA II KSL00355

Страница 1: ...THERMA THERMA II Installation and maintenance guide Electronic wall mounted faucet...

Страница 2: ...any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular purpose or non infringement Kassel Sanitar S L assumes no responsib...

Страница 3: ...ey 1 x 2 mm Allen key 1 x Faucet body and spout Familiarize yourself with the part names and confirm that the parts are included 1 x Faucet body 1 x Spout 2 x Eccentric unions 2 x Fixation accessories...

Страница 4: ...nt All plumbing is to be installed in accordance with applicable codes and regulations Faucet installation STEP 1 INSTALLINGTHE Faucet 1 Shut off the water supply NOTE The standard distance between th...

Страница 5: ...SEC TIONTITLED SETTING ADJUSTMENT The faucet has been factory calibrated to 38 C under ideal installation conditions Due to variations in site conditions the mixed water temperature may need adjustme...

Страница 6: ...he button once Securitytime The Security time prevents continuous flushing of water due to reflections or vandalism By default if the sensor is covered for more than 90 seconds the water flow will shu...

Страница 7: ...er protec tion and disconnect the connec tor between the battery and the electronic unit 3 Take out the old battery 4 Replace the used battery with a new 9V battery a Lithium battery is recommended an...

Страница 8: ...e of reflection 2 Sensor is picking up reflections from the washbasin or another object Remove clean re install Filter or aerator is clogged Water flow diminished TROUBLESHOOTING KASSEL SANIT R S L wa...

Страница 9: ...Kassel Sanit r S L Avda de Castilla 1 Pol gono Industrial 28830 San Fernando de Henares Madrid Spain Daimlerstra e 2 D 93133 Burglengenfeld Germany Tel 34 916 778 993 Fax 34 916 777 774 info kassel e...

Отзывы: