P a g e

 

OUTPUT MUTE SWITCHES 

A very practical feature when running larger sound systems are the 2 
mute switches - one per channel – on the front panel of the power 
amplifier. The red LED indicates the MUTE is ON or activated. Each 
amplifier output can be isolated. There is also a green "signal present 
LED" that indicates any audio source above - 30dB.  

 

 

AUDIO LINE TRANSFORMER 

If you run very long line feeds and especially when using different 
power circuits, one should have a power transformer balancing to avoid ground hums. This will 
avoid as well electromagnetic  problems caused by engines or light fixtures and dimmers. The best 
results are usually achieved by leaving the signal line one sided ground free, which means the 
protection is disconnected from Pin 1. Even unbalanced cables can be connected in the same way 
by having the power balanced side only at Pin2 and 3. The digital input has always a transformer 
built-in. 
 

POWER SUPPLY 

The KS AUDIO 

TA 2D

 power amp uses a state-of-the-art, heavy duty and wide-range switch mode 

design, with Power-Factor-Correction (PFC) built in. This power supply will accept any AC input 
from 100–240V, 50/60Hz. It is connected via a Blue Neutrik®-powerCON AC connector with 
protective leader.  
 
As the power amplifier unit is properly grounded, please ensure, for your own safety, that the 
power circuit you are plugging into is properly grounded as well. KS AUDIO amplifiers are very 
efficient, therefore, the demand for electricity is quite low. Please Note: Be sure that the actual 
current draw for all speakers on the supply circuit does not exceed the maximum fuse rating on 
each amplifier. After switching the amplifier on with the MAINS switch, a soft-start is activated first. 
This is to protect the system and all the components involved.  
 
Once the electronic protection circuits have confirmed that the system is running under normal 
conditions, the outputs are activated and the amplifier is ready to operate.  
 
A second wide range and heavy duty switch mode power supply, with PFC, is used to 
independently supply the controller electronics along with the low voltage cooling fans and, the 
stand-by ON/OFF system, via the KS remote digital controller system. 
 

COOLING 

In the production of high output, high levels of heat are also generated as a by-product at the 
amplifier, which could damage the semiconductors. The reduction of these high temperatures is 
done with the installation of 2 independent operating cooling fans, controlled in their speed / 
efficiency by the heat. The air is socked in from the front of the power amplifier and passed through 
to the back while passing the cooling fans and the power transformer and actively cool these units. 
 

PROTECTION 

In standard operating mode the controller limits the signals to the drivers. When starting the power 
amp the delay of an 80A relais is protecting the drivers. If the dc voltage is changed to critical level 
a special protection circuit disconnects the speakers from the amplifier. The same protection takes 
place if electrical shortage or low impedance occurs. As soon the reason for the disturbance 
disappears the circuit goes back to its full operation. If the internal heat increases above 85 C ( F ), a 

Содержание TA 2D

Страница 1: ...HE ULTIMATE SUBWOOFER TOOL USER MANUAL TA 2D 2 CHANNEL POWERAMP Thank you for purchasing a professional KS AUDIO product Please carefully follow the instructions in this manual to ensure long trouble...

Страница 2: ...where they exit 11 Make sure the power cord remains readily accessible at all times 12 Only use attachments accessories specified by the manufacturer 13 Unplug device during lightning storms or when u...

Страница 3: ...MER 8 POWER SUPPLY 8 COOLING 8 PROTECTION 8 DANTE OPTION 9 KS REMOTE CONTROL 9 DISPLAY 9 CONTROLS 9 CHANGING VALUES 9 MENU CONFIGURATION OVERVIEW 10 DIMENSIONS 11 SPECIFICATIONS 12 CLEANING OF AMPLIFI...

Страница 4: ...at 4 ohms 2 channel amplifier with MOSFET technology This manual should help you to easily use this product Please read this manual carefully and do not hesitate contacting KS AUDIO headquarter or you...

Страница 5: ...amplifier with MOSFET technology 1 standby switch with LED 2 mute switches channel 1 2 3 mute switch LED s 1 2 red mute 4 encoder knob 5 line direction knobs enter escape 6 ventilation grill screws 7...

Страница 6: ...as well for recording studios or commercial industrial applications Please check when opening the packaging that there are no obvious damages due to transportation which could do harm to the product o...

Страница 7: ...installations a transformer balanced output is preferable to avoid ground differentials and 50 Hz hum loops over mixed type cable runs The impedance is 2 x 10kOhm and is discreet independent for pin...

Страница 8: ...cept analog sources as well Highest end 27 bit Sigma Delta converters in gain stacking along with a 64 times oversampling and a A rated signal to noise ratio of 110dB handle the conversion from analog...

Страница 9: ...e low Please Note Be sure that the actual current draw for all speakers on the supply circuit does not exceed the maximum fuse rating on each amplifier After switching the amplifier on with the MAINS...

Страница 10: ...perated via a rotary pulse transmitter with short stroke switches as well as 4 directional and 2 input keys The menu navigation in the display is intuitive and leads immediately to an applicable Resul...

Страница 11: ...TA 2D 2 CHANNEL POWER AMP TA 2D OPERATING INSTRUCTIONS 10 P a g e MENU CONFIGURATION OVERVIEW...

Страница 12: ...TA 2D 2 CHANNEL POWER AMP TA 2D OPERATING INSTRUCTIONS 11 P a g e DIMENSIONS...

Страница 13: ...impedance min 2 ohms per channel power supply switch mode power supply with PFC mains voltage powercon input 100 250VAC amplification mode Class H MOSFET 3 rails supply input connectors 2x XLR3 in 2x...

Страница 14: ...ive the system as much time as possible to heat up to venue temperature before powering on Of course direct exposure to liquids is never safe and should be prevented at all times The vibrations of a t...

Страница 15: ...ght days 24 month limited warranty of manufacturer to the exclusion of all further claims and the following obligations Exchange or repair of defect devices whenever not subject of external damage van...

Страница 16: ...to comply with the relevant fundamental safety and health criteria of the applicable EC respectively EU directives This declaration shall cease to be valid if alternations are made to the equipment w...

Страница 17: ...r system carried e g from cold truck to warm and humid event location always allow equipment to acclimate for a while For rail cargo use professional shock absorbing flight cases To protect your equip...

Страница 18: ...in the output stage of the equalizer a post oscillation of the impulse response On top of all this the mass of the driver creates an additional post oscillation initiated by the same impulse Combined...

Страница 19: ...over points Instead of a phase shift as found in an analog cross over in the KS AUDIO digital process the time domain of the low pass signal is only considered and the rest of the process follows this...

Страница 20: ...R AMP TA 2D OPERATING INSTRUCTIONS 19 P a g e NOTES CONTACT KS BESCHALLUNGSTECHNIK GMBH WESTENDSTRASSE 1 D 67310 HETTENLEIDELHEIM fon 49 6351 12744 0 fax 49 6351 12744 25 www ks audio de Model Serial...

Отзывы: