OPERATION 

 

KS AUDIO recommends using KS AUDIO SYSTEM-AMPS with KS AUDIO SYSTEM-

LOUDSPEAKERS only! If not, it may damage parts of equipment. 

F MOD  DIGITAL CONTROLLER CARD 

Please check details in the F MOD controller card manual. 
 
 

AUDIO CONNECTORS – LINE IN/OUT 

 

 
 
 
 
 
 

 

All line/audio input and output connections are a balanced electronic type conforming to the XLR 
international standard, nominal 20 KOhms for matching to a typical 50 ohm impedance line output 

(grounding  is  on  pin  #1).  For  very  long  cable  run 
installations,  a  transformer-balanced  output  is 
preferable  to  avoid  ground  differentials  and  60  Hz 
hum  loops  over  mixed  type  cable  runs.  The 
impedance  is  2  x  10kOhm  and  is  discreet 
(independent  for  pin  2  and  3).  Multiple  devices  can 
share the same input signal by using the male-female 

sockets as a daisychained audio link. A total of only 1 dB of signal loss on the input signal is seen 
when up to 20 devices are sharing the same input signal. Digital AES/EBU lines should be run with 
110  Ohm  cable  impedance.  You  can  daisy  chain  as  many  products  you  wish,  as  the  XLR  male 
outputs feature an active line transmitter.  
 
 

UNBALANCED INPUT CONNECTIONS  

Cable  should  be  connected  to  Pin1  and 
Pin3  of  XLR  socket  when  audio  is  input 
under unbalanced. However,  the  best  way 
is  to  connect  Pin3  to  the  shielding  line, 
which will probably bring interference.  
 

 
 

KS AUDIO recommends employing 

"balanced input connections”. 

 

 
 

 

 

POWER-OUTPUTS /SPEAKON 

There  are  4  Neutrik®-Speakon  speaker  level  output  connectors.  These  4  audio  outputs  are 
configured automatically by the controller card selected for the system. The bi-amp mode is +1 /-1 
for  the  lows/mids  and  +2  /-2  for  the  tweeter.  In  bridge  mode  for  high-power-subwoofer 
applications  one  amp  is  on  +1/+2  while  the  other  amplifiers  runs  as  -1/-2.  The  selected 

Содержание CA 4D

Страница 1: ...USER MANUAL CA 4D 4 CHANNEL POWERAMP Thank you for purchasing professional KS AUDIO product Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment...

Страница 2: ...here they exit from the apparatus 11 Make sure the power cord remains readily accessible at all times 12 Only use attachments accessories specified by the manufacturer 13 Unplug this apparatus during...

Страница 3: ...HNOLOGY 7 POWER SUPPLY 7 COOLING 8 PROTECTION SYSTEMS 8 OPERATION 9 F MOD DIGITAL CONTROLLER CARD 9 AUDIO CONNECTORS LINE IN OUT 9 UNBALANCED INPUT CONNECTIONS 9 POWER OUTPUTS SPEAKON 9 OUTPUT MODES 1...

Страница 4: ...into 4 ohms with control card system configuration technology using an optinal digital controller card exclusively supporting the KS Audio FIRTEC finite impulse response technology When changing contr...

Страница 5: ...producing the highest quality of audio possible every time including major recording studios as well as other commercial and industrial applications Virtually every configuration is possible includin...

Страница 6: ...tches corresponding to the 4 audio channels on the amplifier each of these switches has 1 red LED located below it to indicate the channel mute status When the LED is ON the channel is muted This feat...

Страница 7: ...post oscillation initiated by the same impulse Combined together these changes in signal motiontiming at the output stage leaves little in common with the original signal KS Audio developed the FIR Fi...

Страница 8: ...tely finished speaker enclosure so this measurement includes the characteristics of the speaker box itself This operation allows each speaker box to be measured and programmed individually in producti...

Страница 9: ...ng over the heat fins and power transformer to actively cool these units down to nominal operating temperatures PROTECTION SYSTEMS As a KS Audio standard of operation the input signal to the amplifier...

Страница 10: ...gnal by using the male female sockets as a daisychained audio link A total of only 1 dB of signal loss on the input signal is seen when up to 20 devices are sharing the same input signal Digital AES E...

Страница 11: ...ES F MOD MODE SPEAKER CONFIGURATION EXAMPLES GREEN STATUS LED POWER OUT CHANNEL 4 CHANNEL PASSIVE 4 X SPEAKER PASSIVE ALL LEDS OFF POWER OUT 1 2 3 4 2 CHANNEL BRIDGE MODE 2 X SUBWOOFER BRIDGE MODE LED...

Страница 12: ...ivated not that the MUTE is active POWER TRANSFORMER If you run very long power line feeds especially when using different power circuits a balancing power transformer should be utilized to avoid grou...

Страница 13: ...witch a soft start is activated first This is to protect the system and all the components involved Once the electronic protection circuits have confirmed that the system is running under normal condi...

Страница 14: ...2 ohms per channel power supply switchmode power supply with PFC mains voltage powercon input 100 250VAC amplification mode Class H MOSFET 3 rails supply input connectors 4x XLR3 in 4x XLR3 out output...

Страница 15: ...CA 4D 4 CHANNEL POWER AMP CA 4D OPERATING INSTRUCTIONS 14 P a g e DIMENSIONS...

Страница 16: ...give the system as much time as possible to heat up to venue temperature before powering on Of course direct exposure to liquids is never safe and should be prevented at all times The vibrations of a...

Страница 17: ...ght days 24 month limited warranty of manufacturer to the exclusion of all further claims and the following obligations Exchange or repair of defect devices whenever not subject of external damage van...

Страница 18: ...to comply with the relevant fundamental safety and health criteria of the applicable EC respectively EU directives This declaration shall cease to be valid if alternations are made to the equipment w...

Страница 19: ...r system carried e g from cold truck to warm and humid event location always allow equipment to acclimate for a while For rail cargo use professional shock absorbing flight cases To protect your equip...

Страница 20: ...R AMP CA 4D OPERATING INSTRUCTIONS 19 P a g e NOTES CONTACT KS BESCHALLUNGSTECHNIK GMBH WESTENDSTRASSE 1 D 67310 HETTENLEIDELHEIM fon 49 6351 12744 0 fax 49 6351 12744 25 www ks audio de Model Serial...

Отзывы: