38
DOORMAX
INCREASE FORCE
DECREASE FORCE
INCREASE A/C TIME
DECREASE A/C TIME
PHOTO BEAM ENABLED
PHOTO BEAM DISABLED
4. OBSTRUCTION FORCE ADJUSTMENT
5. AUTOMATIC CLOSING
6. PHOTO ELECTRIC SAFETY BEAM
7. OPEN / STOP / CLOSE TERMINALS
CAUTION:
the obstruction force adjustment is set
automatically during programming. Normally no adjustment is
necessary.
a) Press and hold the
button until 3 appears on the
SET
display then release the button. The unit is now in force
adjustment mode.
b) Press the
button to increase the force setting or the
UP
DOWN
button to decrease the force setting. The Maximum
force is 5 and the minimum is 1.
c) Press
to confirm your setting
SET
NOTE:
The force is set on 3 as standard in factory.
NOTE: It is necessary to install Safety Photo Beams in any
installation where the Auto Close function is enabled.
a) Press and hold
button until a horizontal bar is indicated
UP
on the display. Now press
button once to set the auto close
UP
time (in minutes).
b) Press
button to increase the time, or
button to
UP
DOWN
decrease the time. The Maximum time is 9 minutes. To disable
Auto Close, set time to zero (0).
c) Press
button to confirm the set.
SET
NOTE:
Make sure the photo beam has been correctly installed
and use Normally Closed contacts to the accessory terminals
of the opener (Fig. 9).
Also note that the photo beam
function must be disabled if NO photo beams are fitted,
otherwise the door cannot be closed, and the LED will
blink once time as an indication.
a) Press and hold the
button until 11 appears on the
DOWN
display. To enable the photo beam option press
again, the
UP
display will indicate a H (enabled) or press
button to
DOWN
disable (display 11) the option.
b) Press
to confirm the set.
SET
The O/S/C facility can be used for an external push button
switch to operate the opener. The switch must have voltage
free normally open contacts (Fig. 10).
AUTO CLOSE
ENABLED
AUTO CLOSE
DISABLED