Service Manual EF 472
19
R E P A I R S
8. Place the closing handle (56) in the vertical position and remove the cover lid (57).
9. Remove the coffee tap (24).
10. Remove the compact brewing unit (58), loosen the four screws (55) and place the
compact brewing unit on one side.
11. Remove the drip tray (59) : Loosen the two locking latches on both sides (f) of the
capsule bay manually.
12. Remove the cup tray or heating plate (42) (depends on machine type) :
If removing heating plate, loosen the screw (3) of the grounding connection first.
Push the tray or heating plate backwards until both plugs (g) are removed from the
housing. Then lift it and remove backwards, diagonally.
13. Remove the side panels (39).
Loosen the two screws (34) on the bottom of the housing and remove the side
panels.
Function test that
can be performed
depend on the degree of
disassembly.
The following function test can now be done:
•
"Pressure and leakage checks" on page 33