11
If you are using batteries as your source of power, remove the 6 phillips screws on the battery
cover located on the front of the control unit. Install the (4) AA Alkaline batteries that are
included. It is very important to make sure each battery is placed in the proper direction.
Replace battery cover and screws.
If you are using the optional AC adapter as your source of power, you will need to remove the
rubber plug on the control unit. Insert the small plug from the transformer into the control
unit. Plug transformer into wall outlet using appropriate caution
If using optional Hydro Generator please follow directions included with the device.
Turn on the hot and cold wall water stops to supply the faucet with water.
Check all connections for leaks.
Adjust mixing valve to the temperature desired.
STEP 4 • Power Connection
Control Module Settings
STEP 5 • Water Connection
INSTALLATION (con’t)
Shut Off Delay: 1s, 10s, 15s
Auto Flush: (15s flush after every 12 inactive hours) ON or OFF
Auto Time Out: 15s, 20s, 25s, 30s, 45s, 1m, 2m, 10m
Shut Off Delay: 1 sec
Auto Flush: OFF
Auto Time Out: 15 sec
Hold for 10s
LED on sensor will turn on & stay lit
Let go of button
LED light will turn off
Place hand/object at desired distance
Make sure the LED is flashing
If the LED is not flashing, you have a
faulty control box or you are out of range
Hold hand/object at desired distance for 5s
LED will have one last long flash, settings are
saved
ON will flush a full cycle if not in use
for 12 hours
ONE CYCLE is based on Auto-Cutoff
time setting
0: Delayed shut-off is 1s
1: Delayed shut-off is 10s
2: Delayed shut-off is 15s
0: 15s max
1: 20s max
2: 25s max
3: 30s max
4: 45s max
5: 1m max
6: 2m max
7: 10m max
Optional Settings:
Factory Default Settings:
Flow controls can be found inside control module after removing the battery cover.
Sensor Setup
Button / Reset Button Procedure
Auto Flush Switch (Default setting: OFF)
Delayed Shut-Off
(Time before water shuts off
after hands leave the faucet)
Auto-Cutoff (Maximum time
water can flow for one cycle)
A
D
B
C
0
1
2
3
4
5
6
7 8 9
0
1
2
3
A
B
C
D
side of the hot water supply line to the hot side of the mixing valve and tighten properly and do
the same for the cold supply line. Do not overtighten. Do not use thread sealant.