5.  Removing the front cover 

 
Electrical connection of the power cable, additional source, external signal, additional sensor, 
and additional heater on the front side under the cover. To access the electrical connection, 
remove the front cover, as shown in the image below: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 1: Removing the front cover 

 
 

 

Imbus 4 

Содержание WP4 LF-502

Страница 1: ...Service manual Heat pump for sanitary water WP4 LF 502 ID 17 16 22 2991 03 6 2017 SLO ...

Страница 2: ... o o This document is copyrighted Any use outside the provisions of the copyright law without the permission of Kronoterm d o o is illegal and punishable by law All previous versions of this document are void We reserve the right to make changes We reserve the right to change this document and for printing errors ...

Страница 3: ...zalo 2 2 Structure of serial number 3 3 Sestavni deli 3 4 Position of Connections and Dimensions 5 5 Removing the front cover 6 6 Removing the housing of the device 7 7 Table of parameters 8 8 Electrical Connection Scheme 9 9 Technical data 10 ...

Страница 4: ...ID 17 16 22 2991 03 3 6 2017 2 Structure of serial number Example W XX YY ZZZZ 1 2 3 4 1 2 3 4 KRONOTERM Year Calendar week Serial number in current year 0001 0002 0003 etc 3 Sestavni deli ...

Страница 5: ...22000016081 16 THERMAL EXPANSION VALVE 2222000011512 17 COMPRESSOR CONDENSER 2222000079857 18 DEHYDRATOR 2222000040789 19 ELECTRONIC CARRIER 2222000078393 20 CONTACTOR 2222000017514 21 SAFETY THERMOSTAT 2222000075866 22 CONTROL RELAY PANEL 2222000077372 23 MAGNESIUM ANODE 2222000079758 24 PRESSURE SWITCH RELAY 2222000071233 25 SCREEN ADJUSTMENT 2222000077396 26 ELECTRONICS COVER 2222000078379 27 C...

Страница 6: ...ions A Connection cold water G1 B Connection heat carrier return G1 C Connection heat carrier lifting conduit G1 D Circulation connection G3 4 E Hot water connection G1 F Connection for removal of water condensation 16 G Connection for additional electric heater 6 4 ...

Страница 7: ... connection of the power cable additional source external signal additional sensor and additional heater on the front side under the cover To access the electrical connection remove the front cover as shown in the image below Figure 1 Removing the front cover Imbus 4 ...

Страница 8: ...ator device it is necessary to remove the housing of the device Thus it is necessary to 1 Unscrew screws on the front and rear cover 2 Remove the front and rear cover 1 3 Remove the left and right half of the housing 2 Figure 2 Removing the housing of the device 1 1 2 2 Imbus 4 Imbus 4 ...

Страница 9: ...ID 17 16 22 2991 03 8 6 2017 7 Table of parameters Look to Service manual for Controller of heat pump for sanitary water OPTITRONIC 2 ID 17 16 14 3991 xx Table of parameters ...

Страница 10: ...ermostat 15 Fan connection pins 5 Fan condenser 16 Optical converter 6 Pressure switch 17 High pressure switch relay 7 Temperature feeler NTC water 18 Additional heater connection pin 8 Temperature feeler NTC air 19 Power supply connection pins 9 Temperature feeler NTC evaporator 20 Contactor 10 Connection pins of additional source 21 Web module 11 Compressor condenser ...

Страница 11: ...OR DISPLAY WEB ANALOG INPUT COMM PORTS PUMP CONTACT EXT INPUT INPUT 230V COMPR L N N L EL HEATER MAG VALVE FAN FAN 1 N FAN 2 12 Q1 Q2 NTC 5 4 3 2 1 7 6 N L L N 8 1 2 14 13 12 11 10 9 8 6 1 6 2 6 3 7 1 7 2 10 1 10 2 1 10 3 9 2 9 1 10 4 8 2 1 8 2 2 24 2 22 23 24 1 12 3 8 2 2 8 2 1 9 3 9 4 14 2 2 3 4 5 7 9 10 11 13 14 15 18 19 20 21 1 1 1 1 2 1 1 3 1 4 1 1 1 1 2 1 1 5 1 1 2 1 2 2 10 2 2 12 3 12 2 12 ...

Страница 12: ...d production Kronoterm d o o Trnava 5e 3303 Gomilsko Tel 00386 3 703 16 20 Fax 00386 3 703 16 33 Web page www kronoterm com E mail info kronoterm com Customer support and service 00386 3 703 16 26 E mail servis kronoterm com ...