background image

 

 

 

 

ID.: 17-16-24-3007-05 

10 

 6.2017

 

 

6.  Technical data 

Product:  

Device for heating DHW with guided air 

Model: 

 

WP2 LF-202S 

WP2 LF-302S 

Thermal power: 

W

 

1850 (3350)* 

Electrical power: 

W

 

440 (1940 )* 

Max. electrical power: 

W

 

560 (65 °C) (2060)* 

El. heater: 

W

 

1500  

Power supply: 

V

 

~ 230 

Refrigerant: 

 

R134a (1,2 kg) – check on data label!!! 
R134a (0,9 kg) – check on data label!!! 

Max. water temperature: 

°C

 

65 

Needed air flow: 

m

3

/h

 

380 / 450 

Protection class: 

 

IP21 

Temperature of intake air: 

°C

 

 From +5 to +35 

El. protection 

A

 

C 16, (~ 230 V) 

Max. allowed pressure in the heat 
pump: 

Mpa

 

2,3 (23 bar) 

* In case the el. Heater is turned on 

DESIGNATION: 

WP2 LF-202S 

WP2 LF-302S 

Volume:  

200 

270 

Height:   

mm 

1698 

2030 

Diameter:   

mm 

635 

Dimensions of the wrapped device 
WxDxH: 

mm 

700x680x1840 

700x680x2175 

Joint mass:  

kg 

128 

145 

Heat exchanger surface:  

m

2

 

0.91 

1.2 

Highest allowed DHW pressure: 

MPa 

1,0 (10 bar) at 95 °C 

Highest allowed working pressure 
in the heat exchanger:  

MPa 

1,0 (10 bar) at 110 °C 

DHW connections: 

 

1'' 

Circulation connections: 

 

¾'' 

 
 

Содержание WP2 LF-202S

Страница 1: ...eat pump for sanitary water WP2 LF 202S WP2 LF 302S ID 17 16 24 3007 05 6 2017 EN SERVICE REVISION SERIAL NUMBER OF THE INTRODUCTION OF CHANGES DATE OF INTRODUCTION OF CHANGES EXCEPTION 01 116240860 18 6 2016 116240875 ...

Страница 2: ... Copyright by Kronoterm d o o This document is copyrighted Any use outside the provisions of the copyright law without the permission of Kronoterm d o o is illegal and punishable by law All previous versions of this document are void We reserve the right to make changes and printing errors ...

Страница 3: ...D 17 16 24 3007 05 2 6 2017 1 Table of Contents 1 Table of Contents 2 2 Structure of serial number 3 3 Components 3 4 Cover removal cover of electronic 7 5 Electrical wiring diagram 8 6 Technical data 10 ...

Страница 4: ... 17 16 24 3007 05 3 6 2017 2 Structure of serial number Example 116390001 WXXYYZZZZ W XX YY ZZZZ 1 2 3 4 1 2 3 4 KRONOTERM Year Calendar week Serial number in current year 0001 0002 0003 etc 3 Components ...

Страница 5: ...ID 17 16 24 3007 05 4 6 2017 ...

Страница 6: ...ING PLATE 2222000076061 15 ELECTRICAL CONNECTION COVER 2222000082093 16 OPTITRONIC 3R CONTROL 2222000040116 17 OPTITRONIC 3R DISPLAY 2222000081478 18 SAFETY THERMOSTAT 2222000048747 19 COMPRESSOR CAPACITOR 2222000045746 20 CONDENSE TANK 2222000076856 21 COMPRESSOR HOLDER 2222000076931 22 FLANGE 2222000082673 23 MAGNESIUM ANODE 2222000081720 24 DISPLAY HOLDER 2222000081065 25 FLANGE SEAL 2222000027...

Страница 7: ...000005924 14 SUPPORTING PLATE 2222000076061 15 ELECTRICAL CONNECTION COVER 2222000082093 16 OPTITRONIC 3R CONTROL 2222000040116 17 OPTITRONIC 3R DISPLAY 2222000081478 18 SAFETY THERMOSTAT 2222000048747 19 COMPRESSOR CAPACITOR 2222000045746 20 CONDENSE TANK 2222000076856 21 COMPRESSOR HOLDER 2222000076931 22 FLANGE 2222000082673 23 MAGNESIUM ANODE 2222000081720 24 DISPLAY HOLDER 2222000081065 25 FL...

Страница 8: ...To get acces to electronic components of the device it is necessary to remove the screws Imbus 4 on the cover of the device Lift the cover up and remove it 1 Push the front cover of the electronic up in the direction of the arrow 2 and pull it out towards you 3 1 2 3 ...

Страница 9: ...pacitor 11 Temperature probe NTC evaporator 4 Pressure switch 12 Optitronic keyboard 5 Temperature probe NTC water 13 Safety thermostat 6 Connecting clips for regulating fan speed 14 Electrical clip 7 Connecting clip for the supply cable 15 Standard supply cable with plug 8 Connectors for the external signal 16 Electric heater ...

Страница 10: ...ID 17 16 24 3007 05 9 6 2017 Picture 1 El Electrical wiring diagram WP2 LF 202S and WP2 LF 302S ...

Страница 11: ... h 380 450 Protection class IP21 Temperature of intake air C From 5 to 35 El protection A C 16 230 V Max allowed pressure in the heat pump Mpa 2 3 23 bar In case the el Heater is turned on DESIGNATION WP2 LF 202S WP2 LF 302S Volume l 200 270 Height mm 1698 2030 Diameter mm 635 Dimensions of the wrapped device WxDxH mm 700x680x1840 700x680x2175 Joint mass kg 128 145 Heat exchanger surface m2 0 91 1...

Страница 12: ...d production Kronoterm d o o Trnava 5e 3303 Gomilsko Tel 00386 3 703 16 20 Fax 00386 3 703 16 33 Web page www kronoterm com E mail info kronoterm com Customer support and service 00386 3 703 16 26 E mail servis kronoterm com ...

Отзывы: