IV - 27
Comfort Control Unit
4.7.13 Menu 4-4 "Manual actuator test"
The actuator test is used to test the actuators installed
on the machine.
An actuator can only be tested if power is flowing
through it. In the manual actuator test the actuator
must therefore be controlled manually for a short time
to be able to determine if there are any errors in the
actuator system.
During the actuator test, the PTO must
not be turning.
The tractor hydraulics must be
deactivated.
During the actuator test, the actuators
are controlled by the system. This may
result in the machine performing
unexpected actions. Because of this,
the test must only be performed from
a safe position outside the area that is
affected by machine parts moved by
the actuators.
Calling the menu
Main menu
4 "Service" is called.
• You can select menu 4-4
with the rotary
potentiometer. The icon is shown in reverse
colours.
• Press the rotary potentiometer.
The display shows menu 4-4 "Manual actuator test".
Selecting the actuator
• Select the actuator with the rotary potentiometer.
The selected actuator is shown in reverse colours.
L400251
L400271
Содержание 5XL-GD
Страница 1: ...Operating instructions No 4282 1GB Short cut feeder wagon 5XL R GD 6XL R GD from Machine no 599 865 ...
Страница 4: ...Foreword ...
Страница 12: ...I 4 General information ...
Страница 17: ...II 5 Safety ...
Страница 22: ...II 10 Safety ...
Страница 76: ...IV 38 Comfort Control Unit ...
Страница 102: ...VII 2 Overwintering ...
Страница 104: ...VIII 2 Recommissioning ...
Страница 106: ...IX 2 Faults causes and removal ...
Страница 124: ...A 18 Appendix ...
Страница 125: ...A 19 Appendix ...