EN
page 42
7. SIGNALS AND ALARMS
The alarm messages are displayed, based upon their meaning.
When displaying "DETERGENT LEVEL" add detergent in the detergent tank (only with
optional "Sensor for Chemicals Low Level").
When displaying "RINSE-AID LEVEL" add rinse-aid chemical in the rinse-aid tank (only with
optional "Sensor for Chemicals Low Level").
When displaying "
DOOR OPEN
" means that the open door does not allow the maneuver
tried, or a wash cycle was in progress, when lifting the door.
TYPE OF ALARM
CAUSE
REMEDIES
B1
BOILER NOT FILLED
Open the water supply valve and verify a proper water
supply flow. Contact Technical Service
B2
BOILER SENSOR FAILURE
Contact Technical Service
B3
BOILER NOT HEATED
Contact Technical Service
B4
FAILURE IN RINSING
Contact Technical Service
B5
BOILER OVERTEMPERATURE
Contact Technical Service
E1
WASH-TANK NOT FILLED
Open the water supply valve.
Contact Technical Service
E2
WASH-TANK SENSOR FAILURE
Contact Technical Service
E3
WASH-TANK NOT HEATED
Contact Technical Service
E5
WASH-TANK OVERTEMPERATURE
Contact Technical Service
E6
TANK DRAINING FAILURE
Check the overflow pipe. Contact Technical Service
E7
WASH PUMP THERMAL RELAY 1
WASH PUMP THERMAL RELAY 2
Contact Technical Service
Table. 2
Содержание KP202E