KROMA
TELECOM
PROFESSIONAL MONITORS BM5309
BM5309
7
1.5.6. Ground Terminals
There are two ground terminals: protective ground and electrical earth or ground
from the power supply. They are normally connected by means of a metal jumper,
but they can be isolated one another by eliminating said jumper, in case it is
necessary to avoid hum pickups due to the installation.
1.5.7. Remote Control Connectors (RS-485 Interface)
They are located at the rear of the video unit. The connectors, in loop through
configuration, are prepared for connection of the KROMA RK-5400 remote
control.This connector, are also useful for to update the futures software versions
Configuration
Terminal 1 - S/C
“ 2 - DATA + (RS485)
“ 3 - RX (RS232)
“ 4 - GND
“ 5 - S/C
“ 6 - TX (RS 232)
“ 7 - DATA - (RS 485)
“ 8 - GND
REM
Figure 1