Krom Schroder DMG S2601 Скачать руководство пользователя страница 1

                

บริษัท เอดีดี เฟอร์เนส จ ำกัด

 

                                 ADD FURNACE CO.,LTD.

 

                                                44 ซอยบรมราชชนนี

 

  70 ถนนบรมรำชชนนี แขวงศำลำธรรมสพน์ เขตทวีวัฒนำ กรุงเทพฯ 10170

 

                                               

โทร

: 02-888-3472  

โทร

:

 

ออกแบ

:

08-08-170-170 

  

แฟกซ์

: 02-888-3258 

 

 

                                               https://www.add-furnace.com   E-mail: 

[email protected]

 

 

13.1.1.5 Edition 07.10 

  

   

 

  D          GB            F 

 

     www.docuthek.com

 

 

Operating instructions  

Electronic pressure gauge  

DMG S2601, DMG S2610 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Translation from the German 

 

© 2008 – 2010 Elster GmbH 

 

 

Electronic pressure gauge ..............................1  
DMG S2601, DMG S2610 .................................1  
Contents ........................................................ 1  
Safety .............................................................1  
Checking the usage ........................................2 

Type code ......................................................... ..2 

 

Part designations  ................................................2 

 

Type label  ...........................................................2 

 

Commissioning ..................................................2 

 

Segment displays ................................................ 2 

 

Connecting the measuring hoses ........................ 2 
Selecting the operating mode ..............................2 

 

ZERO (zero point calibration) operating mode .....

 

UNIT (unit selection) operating mode  ..................

AUTO (measured value resolution) operating  
mode ................................................................3 
Min./Max. measured value  ..................................

 

Hold function  .......................................................

 

Display lighting  ....................................................3 

 

Switching off .........................................................3 

 

Maintenance ....................................................3  

Changing the batteries...................................... 3 

 

Accessories .....................................................4  
Assistance in the event of malfunction............4 
Technical data ....................... .........................4 
 Declaration of conformity ..............................4 

 
 
 
 

 
 
 
 
 
 
 

 
Please read and keep in a safe place 

                  
                      
                 Please read through these instructions  
carefully before installing or operating. Follow-ing the 
installation, pass the instructions on to the operator. 
These instructions can also be found at 

www.docuthek.com

. 

 

Explanation of symbols 

●   

, 1   , 2  , 3  

...= Action

 

           

= Instruction 

Liability 

We will not be held liable for damages resulting from 
non-observance of the instructions and non-compliant 
use. 

Safety instructions 

Information that is relevant for safety is indicated in the 
instructions as follows:

  

      

DANGER 

Indicates potentially fatal situations.

      

       

WARNING

 

Indicates possible danger to life and limb.

    

   

!

    

CAUTION 

Indicates possible material damage. 
 
All interventions may only be carried out by qualified 
gas technicians. Electrical interventions may only be 
carried out by qualified electricians. 

Conversion, spare parts 

All technical changes are prohibited. Only use OEM  
spare parts. 

Transport 

On receipt of the product, check that the delivery is 
complete (see Part designations). Report any trans-port 
damage immediately.  

Storage 

Store the product in a clean, dry environment, protected 
from shocks. Ambient temperature: see Technical data. 

Disposal 

Components, particularly batteries, are to be dis-posed 
of separately. 
On request, old units may be returned carriage paid to 
Elster GmbH in accordance with the relevant waste 
legislation requirements (for Germany: KrW-/AbfG [Act 
for Promoting Closed Substance Cycle Waste 
Management and Ensuring Environmentally Compat-
ible Waste Disposal]). 
 

 
 

Contents 

 

Safety 

Содержание DMG S2601

Страница 1: ... instructions on to the operator These instructions can also be found at www docuthek com Explanation of symbols 1 2 3 Action Instruction Liability We will not be held liable for damages resulting from non observance of the instructions and non compliant use Safety instructions Information that is relevant for safety is indicated in the instructions as follows DANGER Indicates potentially fatal si...

Страница 2: ...es and 2 Magnet 3 Display 4 Connections 5 On Off button 6 Menu button unit selection 7 Program selection button 8 Pause button 9 Min Max button Type label Model serial number and measuring range see type label Segment displays 1 Switching on the DMG Press the On Off button for approx 1 s All the available display segments are displayed for approx 2 s The segment display time can be extended for ch...

Страница 3: ...w resolution Min Max measured value 1 Press min max button The display shows the minimum measured pressure value 2 Press min max button again The display shows the maximum measured pressure value 3 To delete the min max measured value press the menu button The current measured pressure value is displayed again Hold function In all operating modes the measured value can be held by pressing the paus...

Страница 4: ... 104 F storage temperature 20 to 50 C 4 to 122 F Approved batteries 2 x 1 5 V type miniature LR6 AA Power supply rated voltage via power adapter USB DMG 2601 measuring range rated 150 mbar 2 2 psi max 180 mbar 2 6 psi max positive pressure 1 35 bar 19 6 psi DMG 2610 measuring range rated 1000 mbar 14 5 psi max 1500 mbar 21 8 psi max positive pressure 3 bar Resolution DMG 2601 0 01 19 99 0 1 20 DMG...