Contents

OPTISOUND3020 C • Two-wire 4 … 20 mA/HART

62687-EN-190926

Contents

1  For your safety ......................................................................................................................... 3

1.1  Authorised personnel ....................................................................................................... 3

1.2  Appropriate use ................................................................................................................ 3

1.3  Warning about incorrect use ............................................................................................. 3

1.4  General safety instructions ............................................................................................... 3

1.5  Safety label on the instrument .......................................................................................... 4

1.6  EU conformity ................................................................................................................... 4

1.7  Fulfillment of NAMUR recommendations ......................................................................... 4

2  Product description ................................................................................................................. 5

2.1  Configuration .................................................................................................................... 5

3 Mounting ................................................................................................................................... 6

3.1  Mounting instructions ....................................................................................................... 6

4  Connecting to power supply ................................................................................................... 7

4.1  Connection procedure ...................................................................................................... 7

4.2  Wiring plan, single chamber housing................................................................................ 8

4.3  Wiring plan, double chamber housing .............................................................................. 8

5  Set up with the display and adjustment module PLICSCOM .............................................. 9

5.1  Insert display and adjustment module .............................................................................. 9

5.2  Setup steps .................................................................................................................... 10

5.3  Menu schematic ............................................................................................................. 12

6 Supplement ............................................................................................................................ 14

6.1  Technical data ................................................................................................................ 14

Information:

This quick setup guide enables quick setup and commissioning of 

your instrument.
You can find further information in the corresponding, comprehensive 

operating instructions as well as in the Safety Manual for instruments 

with SIL qualification.

Operating instructions OPTISOUND 3020 C - Two-wire 

4 … 20 mA/HART: Document-ID 30507

Editing status of the quick setup guide: 2019-09-25

Содержание OPTISOUND3020 C

Страница 1: ...OPTISOUND3020 C Quick setup guide Ultrasonic Level Transmitter Two wire 4 20 mA HART...

Страница 2: ...7 4 2 Wiring plan single chamber housing 8 4 3 Wiring plan double chamber housing 8 5 Set up with the display and adjustment module PLICSCOM 9 5 1 Insert display and adjustment module 9 5 2 Setup ste...

Страница 3: ...ty and persons or environmental contamination can result Also the protective characteristics of the instrument can be impaired 1 4 General safety instructions This is a state of the art instrument com...

Страница 4: ...E marking we confirm the conformity of the instrument with these directives The EU conformity declaration can be found on our homepage 1 7 Fulfillment of NAMUR recommendations NAMUR is the automation...

Страница 5: ...onfiguration The type label contains the most important data for identification and use of the instrument Instrument type Article and serial number device Article number documentation Technical data A...

Страница 6: ...plane the so called dead zone in which measurement is not possible is maintained The exact value of the dead zone is stated in chapter Technical data 1 2 Fig 1 Minimum distance to the max level 1 Dea...

Страница 7: ...e sensor through the cable entry 6 Lift the opening levers of the terminals with a screwdriver see following illustration 7 Insert the wire ends into the open terminals according to the wir ing plan F...

Страница 8: ...6 4 2 Wiring plan single chamber housing I2C Display 1 1 2 5 6 7 8 Fig 4 Wiring plan single chamber housing 1 Voltage supply signal output 4 3 Wiring plan double chamber housing I2C 1 1 2 Fig 5 Wiring...

Страница 9: ...on on the electronics you can choose any one of four different posi tions each displaced by 90 3 Press the display and adjustment module onto the electronics and turn it to the right until it snaps in...

Страница 10: ...menu item Medium the medium of your applica tion for example Aqueous solution Medium Liquid 4 Select in the menu item Application the vessel the application and the vessel form for example Storage ta...

Страница 11: ...el walls cause interfering reflections which can impair the measurement A false echo storage detects and marks these false echoes so that they are no longer taken into account for the level measuremen...

Страница 12: ...atic Information Depending on the version and application the highlighted menu windows may not always be available Basic adjustment Basic adjustment 1 Display Diagnostics Service Info Min adjustment 1...

Страница 13: ...adjustment 4 Display Diagnostics Service Info False signal suppression 4 1 Change now Extended setting 4 2 None Current output 4 3 Characteristic 4 20 mA Fail mode 3 6 mA Min current 3 8 mA Simulatio...

Страница 14: ...5 ft Bulk solids up to 3 5 m 11 48 ft Dead zone 0 4 m 1 312 ft Electromechanical data Cable entry Single chamber housing 1 x cable gland M20 x 1 5 cable 5 9 mm 1 x blind plug M20 x 1 5 or 1 x closing...

Страница 15: ...15 Notes OPTISOUND3020 C Two wire 4 20 mA HART 62687 EN 190926...

Страница 16: ...rs Vortex flowmeters Flow controllers Level meters Temperature assemblies Pressure transmitters Analysis products Products and systems for the oil and gas industry KROHNE Messtechnick GmbH Co KG Ludwi...

Отзывы: