2

CAUTION!

If there is excessive vibration in the process pipework, you must isolate the meter from its
mounting. It is recommended that you place an insert made from rubber (or similar material) 
between the meter body, or pipework, and the mounting clamp or 

fi

 xing point. For more 

information, contact the manufacturer.

Danger:

• Turn 

o

  the power supply before working on electrical connections.

• 

Check the voltage data on the nameplate

• 

Observe national regulations for electrical installations

• 

The device MUST be grounded in accordance with regulations to protect personnel 
against electric shock

Vibration from pumps and other equipment in the process line can have an e

 ect on the meter that, in 

some situations, can cause damage. Damage is most likely to occur if the meter has hygienic
connections and the level of vibration is excessive.

Excessive vibration

2 Electrical connections

Compact

Procedure

1.  Unscrew the housing cover 

1

2.  Open the touch guard 

2

3.  Put the electrical cable through the related 

cable gland

4.  Connect the electrical wires 

3

5.  Close the touch guard 

2

6.  Put the signal cable/s through the related cable 

gland/s

7.  Connect the signal cables 

4

8.  Replace the housing cover and tighten it with 

your hand 

5

Remote

Signal cable preparation 

The signal cable is made up of 

fi

 ve (twisted) pairs of cables. Each pair also has a drain wire and the 

three wires are covered in a foil wrap. The 

fi

 ve cable pairs are covered in an outer foil wrap and a braided 

screen. The complete cable is protected by a PVC outer sheath 

1

 Outer Sheath

2

 Braided screen 

3

  Outer foil wrap

4

 Foil wrap 

5

 Cable pairs

6

 Drain wires

Strip back all the foil wraps and discard them. Unwrap the braided screen so that it can be twisted to form 
a connection underneath the earth clamp. Bend all 

fi

 ve drain wires back and twist them together with the 

braided screen. 

It is important that ALL 

fi

 ve drain wires AND the braided screen form part of the shielding.  

MFC 400 Remote

Wall mount

Field mount

The label (above) on the inside of the terminal 
compartment lid, gives information about out-
put connections. 

04/2020 - 4008121701- QS-OPTIMASS 1400-R01- en