background image

2

 DEVICE DESCRIPTION 

OPTIBAR DP 7060

www.krohne.com

05/2017 - 4005720001 - AD OPTIBAR 7060 Ex db ia R01en

2.6  Ambient temperature / temperature classes

OPTIBAR DP 7060 VGK7*A/W/V E/Z/6/7 with integrated electronics Z (4

OPTIBAR DP 7060 VGK7*A/W/V E/Z/6/7 with integrated electronics Z (4

OPTIBAR DP 7060 VGK7*A/W/V E/Z/6/7 with integrated electronics Z (4

OPTIBAR DP 7060 VGK7*A/W/V E/Z/6/7 with integrated electronics Z (4

20 mA), 

20 mA), 

20 mA), 

20 mA), 

H (4

H (4

H (4

H (4

20 mA/HART) or A (4

20 mA/HART) or A (4

20 mA/HART) or A (4

20 mA/HART) or A (4

20 mA/HART

20 mA/HART

20 mA/HART

20 mA/HART

®

 with SIL qualification), P (Profibus PA), F 

 with SIL qualification), P (Profibus PA), F 

 with SIL qualification), P (Profibus PA), F 

 with SIL qualification), P (Profibus PA), F 

(Foundation Fieldbus)

(Foundation Fieldbus)

(Foundation Fieldbus)

(Foundation Fieldbus)

The maximum permissible ambient temperatures depending on the temperature classes are 
specified in the following tables. 

Category 1/2G equipment

Category 1/2G equipment

Category 1/2G equipment

Category 1/2G equipment

For applications requiring equipment category 1/2G, the process pressure of the media must be 
between 0.8

1.1 bar. If OPTIBAR DP 7060 VGK7*A/W/V E/Z/6/7 are operated at temperatures 

higher than those specified in the table above, please make sure by means of appropriate 
measures that there is no danger of ignition from the hot surface. The maximum permissible 
temperature of the electronics/housing should not exceed the values given in the table above.  
The application conditions in areas without hazardous mixtures are specified in the 
manufacturer information.

Category 2G equipment

Category 2G equipment

Category 2G equipment

Category 2G equipment

 If OPTIBAR DP 7060 VGK7*A/W/V E/Z/6/7 are operated at temperatures higher than those 
specified in the table above, please make sure by means of appropriate measures that there is 
no danger of ignition from the hot surface. The maximum permissible temperature of the 
electronics/housing should not exceed the values given in the table above.  The application 
conditions in areas without hazardous mixtures are specified in the manufacturer information.

Temperature class

Ambient temperature range at 
the electronics (zone 1)

Media temperature range at the 
sensor (zone 0)

T1, T2, T3, T4

-40...+60

°

C / -40...+140

°

F

-40...+60

°

C / -40...+140

°

F

T5, T6

-40...+46

°

C / -40...+114.8

°

F

-40...+46

°

C / -40...+114.8

°

F

Temperature class

Ambient temperature range at 
the electronics (zone 1)

Media temperature range at the 
sensor (zone 0)

T1, T2, T3, T4

-40...+60

°

C / -40...+140

°

F

-40...+60

°

C / -40...+140

°

F

T5, T6

-40...+46

°

C / -40...+114.8

°

F

-40...+46

°

C / -40...+114.8

°

F

Содержание OPTIBAR DP 7060

Страница 1: ...uminium Single chamber double chamber Stainless steel precision casting Single chamber double chamber OPTIBAR DP 7060 OPTIBAR DP 7060 OPTIBAR DP 7060 OPTIBAR DP 7060 Supplementary Instructions Supplem...

Страница 2: ...With electronics Z 4 20 mA H 4 20 mA HART A 4 20 mA HART with SIL qualifica tion 10 2 7 2 With electronics P Profibus PA F Foundation Fieldbus 11 2 7 3 With separate cable outlet 11 3 Installation 12...

Страница 3: ...le for use in hazardous atmospheres of all combustible materials of explosion group IIA IIB and IIC for applications requiring category 1 2G or 2G equipment When the OPTIBAR DP 7060 VGK7 A W V E Z 6 7...

Страница 4: ...use of the device which have been listed in these instructions If needed the IEC certificate can be downloaded from the manufacturer s website 1 4 Safety instructions Assembly installation start up a...

Страница 5: ...ng for ATEX The marking of the entire device is on the housing where the following identification plate can be found Figure 2 1 Example for an ATEX nameplate for a OPTIBAR DP 7060 1 Approvals and Ex d...

Страница 6: ...st mixtures no key figures are available for the ignition behaviour Operating conditions Operating conditions Operating conditions Operating conditions Outside of atmospheric conditions the explosion...

Страница 7: ...safe circuits d ia according to EN 60079 1 EN 60079 11 and IEC 60079 1 IEC 60079 11 however the device does NOT NOT NOT NOT require an intrinsically safe supply The marking according to ATEX is II 1 2...

Страница 8: ...V E Z 6 7 are operated at temperatures higher than those specified in the table above please make sure by means of appropriate measures that there is no danger of ignition from the hot surface The ma...

Страница 9: ...0 131 F 40 85 C 40 185 F 1 40 60 C 40 140 F 40 72 C 40 161 6 F 40 85 C 40 185 F 1 40 50 C 40 122 F 40 85 C 40 185 F 40 85 C 40 185 F 1 40 40 C 40 104 F T5 T6 40 46 C 40 114 8 F 40 55 C 40 131 F 1 40 4...

Страница 10: ...n with single chamber housing A V Supply and signal circuit Terminals 1 2 in electronic compartment Indicating and adjustment circuits terminals 5 6 7 8 Ui 9 6 35 VDC Um 253 VAC Circuit for the displa...

Страница 11: ...i 9 32 VDC Um 253 VAC Circuit for the display and adjustment module spring contacts in the electronic compartment For connection to the display and adjustment module OPTIBAR DP 7060 VGK7 A W V E Z 6 7...

Страница 12: ...ervoltage protection in the event of lightning or overvoltage they are not in a pneumatic flow excessive dust deposits over 5 mm and complete dust coverage are prevented there is no danger from mechan...

Страница 13: ...re transmitter of the OPTIBAR 7060 series is designed to measure the pressure of vaporous gaseous and liquid media The differential pressure transmitters are supplied as standard with 2 wire 4 20 mA s...

Страница 14: ...nstallation of an Ex d cable entry certified according to EN 60079 1 or IEC 60079 1 Simple cable entries should not be used Refer to sections 13 1 and 13 2 of EN 60079 1 or IEC 60079 1 When connecting...

Страница 15: ...locking screw of the cover until it stops Unused openings must be sealed according to EN 60079 1 or IEC 60079 1 paragraph 11 9 The cover of the Ex d electronic compartment has the warning label Do no...

Страница 16: ...f thread for the Ex d cable entries The Ex d terminal compartment of OPTIBAR DP 7060 VGK7 A W V E Z 6 7 with cable entry type 0 D or 6 has cable entries M20 x 1 5 The Ex d terminal compartment of OPTI...

Страница 17: ...device must be removed prior to start up The openings must be closed prior to start up using a method permitted for the protection type Permitted and suitable cable glands or plugs must be installed i...

Страница 18: ...5 NOTES 18 OPTIBAR DP 7060 www krohne com 05 2017 4005720001 AD OPTIBAR 7060 Ex db ia R01en...

Страница 19: ...NOTES 5 19 OPTIBAR DP 7060 www krohne com 05 2017 4005720001 AD OPTIBAR 7060 Ex db ia R01en...

Страница 20: ...ces Head Office KROHNE Messtechnik GmbH Ludwig Krohne Str 5 47058 Duisburg Germany Tel 49 203 301 0 Fax 49 203 301 10389 info krohne com KROHNE 05 2017 4005720001 AD OPTIBAR 7060 Ex db ia R01en Subjec...

Отзывы: