1.1  Safety instructions from the manufacturer

1.1.1  Disclaimer

The manufacturer will not be liable for any damage of any kind by using its product, including, 
but not limited to direct, indirect or incidental and consequential damages. 

This disclaimer does not apply in case the manufacturer has acted on purpose or with gross 
negligence. In the event any applicable law does not allow such limitations on implied warranties 
or the exclusion of limitation of certain damages, you may, if such law applies to you, not be 
subject to some or all of the above disclaimer, exclusions or limitations. 

Any product purchased from the manufacturer is warranted in accordance with the relevant 
product documentation and our Terms and Conditions of Sale. 

The manufacturer reserves the right to alter the content of its documents, including this 
disclaimer in any way, at any time, for any reason, without prior notification, and will not be liable 
in any way for possible consequences of such changes.

1.1.2  Product liability and warranty

The operator shall bear responsibility for the suitability of the device for the specific purpose. 
The manufacturer accepts no liability for the consequences of misuse by the operator. Improper 
installation or operation of the devices (systems) will cause the warranty to be void. The 
respective "Standard Terms and Conditions" which form the basis for the sales contract shall 
also apply.

1.1.3  Information concerning the documentation

To prevent any injury to the user or damage to the device it is essential that you read the 
information in this document and observe applicable national standards, safety requirements 
and accident prevention regulations.

If this document is not in your native language and if you have any problems understanding the 
text, we advise you to contact your local office for assistance. The manufacturer can not accept 
responsibility for any damage or injury caused by misunderstanding of the information in this 
document.

This document is provided to help you establish operating conditions, which will permit safe and 
efficient use of this device. Special considerations and precautions are also described in the 
document, which appear in the form of icons as shown below.

Содержание M-PHASE 5000

Страница 1: ...hase flowmeter M PHASE 5000 M PHASE 5000 M PHASE 5000 M PHASE 5000 Supplementary Instructions Supplementary Instructions Supplementary Instructions Supplementary Instructions KROHNE 04 2016 4004673401...

Страница 2: ...ning the documentation 3 1 1 4 Warnings and symbols used 4 1 1 5 Manufacturer 4 1 2 Safety instructions for the operator 5 1 3 Approvals 6 1 4 General 6 1 5 Marking label 8 2 Temperature limits 10 2 1...

Страница 3: ...es of such changes 1 1 2 Product liability and warranty The operator shall bear responsibility for the suitability of the device for the specific purpose The manufacturer accepts no liability for the...

Страница 4: ...rking with electricity DANGER This warning refers to the immediate danger of burns caused by heat or hot surfaces DANGER This warning refers to the immediate danger when using this device in a hazardo...

Страница 5: ...cal equipotential bonding system of the potentially explosive area Components attached or installed junction boxes bushings Ex type cable glands connectors shall be of a technical standard that compli...

Страница 6: ...0 2012 EN 60079 1 2014 EN 60079 7 2007 EN 60079 18 2015 EN 60079 28 2015 1 4 General The electronic boxes Ex d contains the following screw type Cylinder head screw Standard ISO4762 Size M8x16 Materi...

Страница 7: ...inals for Power and Signal connections all in type of protection Ex e For electrical data of these terminals refer to section 3 2 The Ethernet is terminated on a connector at the outside of the field...

Страница 8: ...nameplate with device details as shown in the following two figures Figure 1 1 Location and details of nameplate 1 Information about manufacturer and product 2 Information about CE and explosion prot...

Страница 9: ...9 M PHASE 5000 www krohne com 04 2016 4004673401 AD M PHASE5000 Ex R01 en Figure 1 2 Location and details of nameplate 1 Information about manufacturer 2 Information about explosion protection 3 Warni...

Страница 10: ...k The instrument is not heated up by any additional heat radiation direct solar radiation heat from adjacent plant parts so causing it to operate above the permissible ambient temperature range Insula...

Страница 11: ...ed cables must be used The shield must be connected to the EMC cable gland The mains power cable has three wires There are different colors used to identify the wire as in table below INFORMATION The...

Страница 12: ...the equipotential bonding system of the hazardous area See IEC 60079 14 clause 6 3 For this purpose the internal or external connection facility PE clamp can be used Figure 3 1 Signal cables and power...

Страница 13: ...orted This means that KROHNE can only service an instrument if it is accompanied by the following certificate confirming that the instrument is safe to handle If the instrument has been operated with...

Страница 14: ...ress Department Name Tel No Fax No The enclosed device Type KROHNE Order No or Series No has been operated with the following liquid Because this liquid is water hazardous radioactive toxic caustic fl...

Страница 15: ...ax No Manufacturer s order no or serial no The device has been operated with the following medium KROHNE Order No or Series No has been operated with the following liquid Because this liquid is water...

Страница 16: ...rvices Head Office KROHNE Messtechnik GmbH Ludwig Krohne Str 5 47058 Duisburg Germany Tel 49 203 301 0 Fax 49 203 301 10389 info krohne com KROHNE 04 2016 4004673401 AD M PHASE5000 Ex R01 en Subject t...

Отзывы: