FAULT FINDING CHART
Technical
problems
Problem
Problem Causes
What To Do
Smell of gas
Regulator & hose connection loose
Use soap form for
leakage control, check
all connection system
replace defected parts
Valve & pipe connection loose
Pipe broken
Missing piece of ceramic fireclay
Inspect perimeter
of each plaque and
locate place where
some fireclay has been
displaced. Repair with
PYRUMA and leave
to set for Approx. 48
hours.
Inefficient combustion on
ceramic burner
Dirty gas inlets
Please clear injectors
with Air
If there is no ignition
Battery no power
Change a AAA battery
Defective Spark - Plug
Check cable of ignitor,
& replace defected
ignitor if necessary
Defective ignitor cable
Check spark – plug
and connections, & re-
place defected ignitor
if necessary
Burner flame has extingui-
sh during operation
Run out of gas
Change the gas bottle
Thermal element has not been
warm enough
Try restarting
Wing or draught has extinguished
the flame
Put the appliance out
of reach of wind and
draught, let it cool
down for a couple of
minutes and try to
restart it
Faulty thermocouple
Replace the faulty
thermocouple
Faulty magnetic valve
Replace the magnetic
valve
general
problem
Heater is not remain alight
when pressure is released
from ignition button
Wrong power setting at first process
Turn the control knob
at “ START” Position
and press for 10 se-
conds, whilst press the
Piezo igniter key to lit
Heater could not be
turned on
Did not connect the gas regulator to
gas cylinder
Connect heater to
the gas cylinder and
ensure there is not
smell, then follow the
Instruction to turn on
the heater
Gas cylinder control is closed
Please turn on the gas
cylinder control
Содержание 50469