BELLOWS (2)

If material leaks under the base of the air motor, at
the leakage indicators, bellows must be replaced.

Proceed as previously explained when filling valve
is removed.

Remove suction body (1) by means of the 4
fastening screws (6).

The bellows is released when suction body is taken
out.

To reinstall the bellows :

fits its lower part (small

diameter) in skirt (3).

Slip bellows on motor rod.

Screw the rod (12) into motor rod after having
installed the seal (4) and the filling valve (5). (The
whole must be slightly glued with Loctite adhesive).

Lock the rod (12) using the motor rod flat.

Insert the suction body after pushing the motor rod
upwards.

Fill the 4 screws (6) and tighen them gradually by
screwing in criss-cross manner. Torque screws (6).

Reinstall the other parts as indicated previously

1

2

3

4

5

12

11

GT SEALS (7 & 16) AND PISTON (11)

Remove the valves.

Remove the suction chamber (17) by unscrewing
the 6 fastening screws (18).

Remove the lower GT seal (16).

Dismount the piston (11). When disassembling :

- Unscrew nut (14) holding rod (2) thanks to the two

flats located above the nut.

- Remove shutter (13).

- Remove piston pulling it downwards.

Remove cylinder (10).

Take off the upper GT seal (7).

Make sure the new seals (7 & 16) are

installed in the proper direction.

Both seals (8 & 15) must be replaced.

When reassembling, carefully insert piston (11) into
seal (7) which is in the reverse order.

Caution : Before tightening the nut (14),

- Place the rod (12) into piston (11).

- Place the piston (11) into the upper part of the

cylinder (10).

- Tighten the nut (14) holding the rod (12).

7

8

15

16

1

12

11

10

Содержание FLOWMAX 17 A2

Страница 1: ...tart up please read and clearly understand all the documents relating to this equipment professional use only THE PICTURES AND DRAWINGS ARE NON CONTRACTUAL WE RESERVE THE RIGHT TO MAKE CHANGES WITHOUT PRIOR NOTICE KREMLIN REXSON l 150 avenue de Stalingrad 93 245 STAINS CEDEX France 33 0 1 49 40 25 25 Fax 33 0 1 48 26 07 16 www kremlin rexson com ...

Страница 2: ... and the ball 28b Change all the seals 29 32 and 35 Clean or change the parts if necessary Assembly Assemble new seals and lubricate them Place the lower stop 30 the ball 28b and the seat support 27b into the intermediate body 31 Guide the parts in the axis unti stop in the intermediate body Insert the seat support 27a until stop into the upper body 36 then locate the ball 28a and the spring 33 Cl...

Страница 3: ...rews 6 and tighen them gradually by screwing in criss cross manner Torque screws 6 Reinstall the other parts as indicated previously 1 2 3 4 5 12 11 GT SEALS 7 16 AND PISTON 11 Remove the valves Remove the suction chamber 17 by unscrewing the 6 fastening screws 18 Remove the lower GT seal 16 Dismount the piston 11 When disassembling Unscrew nut 14 holding rod 2 thanks to the two flats located abov...

Страница 4: ...k in the reverse order of the disassembly sequence CAUTION The number of spirals must equally be distributed on each fastening parts in order to get the above dimension 31 85 mm 0 5 When reassembling the different components Clean the parts with the appropriate cleaning solvent Install new seals if necessary after having lubricated them with PTFE grease Lubricate the piston and the inside of the c...

Страница 5: ... 29 29 29 33 36 35 34 30 31 38 32 27 28 37 32 27 28 38 29 26 A 1 A 1 A 1 A 1 A 1 C 1 A 1 A 1 Ind 25 Index Instructions Description Part number PTFE grease TECHNILUB grease 10 ml 560 440 101 Medium strength Aneorobic Pipe Sealant Similar as Loctite 577 Low strength Aneorobic Adhesive Loctite 222 Screwing torque 40 Nm 29 5 ft lbs A 1 C 1 S 1 C 2 ...

Отзывы: