KREMLIN REXSON
Page 2
Manual : 573.032.212
DIMENSIONS
Ind.
mm
"
Ind.
mm.
"
Ind.
mm
"
Ind.
mm
"
A
470
18.5
B
220
8.7
C
975
38.4
D
270
10.63
E
182
7.16
F
35
1.38
G
36,5
1.43
H
60
2.36
I
211,5
8.3
J
Ø 7x 15 Ø 0.27x0.6
K
Ø 17
Ø 0.67
L
Ø 9
Ø 0.35
M
Ø 9
Ø 0.35
D
C
B
A
E/F
E
G
H
F
I
J
K
L
M
=
=
2. SERVICING
WARNING :
Before any action on the pump, shut off the compressed air supply and
depressurize the systems by triggering the spray gun.
The pump is manufactured under the ATEX agreement and can not be modified.
KREMLIN REXSON will not be held responsible for any failure to comply with that
instruction.
DISASSEMBLY / REASSEMBLY OF THE FLUID SECTION
Guards (motor cover, coupling shields, connectors,…) have been designed for a
safe use of the equipment.
The manufacturer will not be held responsible for bodily injury or failure and / or
property damage due to destruction, the overshadowing or the partial or total
removal of the guards.
Unscrew the fitting (38) and the screws (41 and 43) to remove the attachment fluid tube (39).