Kremlin-Rexson AIRMIX 08-120 Скачать руководство пользователя страница 2

KREMLIN REXSON 

- 1 - 

N° :  578.166.110-UK-1411 

 

CAUTION :  

Before any action on the pump, shut off the compressed air supply and 
depressurize the system.  
 

The pump is manufactured under the ATEX agreement and can not be modified. 

KREMLIN REXSON will not be held responsible for any failure to comply with that instruction. 

Guards (air motor cover, coupling shields, housings …) have been designed for 

safe use of the equipment. 

The manufacturer will not be held responsible for bodily injury or failure and / or 

damage to property due to removal or partial removal of the guards 

 

SUCTION VALVE (REFER TO DOC. 573.049.050) 

Unscrew  suction  valve  (16)  -  (If  cylinder  (2)  remains  attached  to  the  suction  valve,  unscrew  the 
whole. Then, hold cylinder (2) by inserting a rod into the cylinder holes designed for this purpose). 

The ball (17) is secured on the valve (16) by means of a circlips (18). 

Clean the parts. 

Reinstall suction valve (16) and seal (19). Replace them if necessary. 

 

CYLINDER 

In order to make easier the disassembly, a hole is drilled in the cylinder (2) at each end. 

In  relation  to  the  part  which  is  unscrewed  first,  insert  a  rod  into  one  of  these  holes  to  unscrew  the 
other part. 

When reassembling be certain the two seals (19) are installed. 

 

EXHAUST VALVE AND MOBILE PACKING 

Unscrew cylinder (2) and pull it downwards. 

Unscrew exhaust valve (6) by holding piston (3). 

Remove ball (8) and mobile packing (cup seal ind. 7). 

Clean the parts and reinstall them. Replace seals if necessary. 

Содержание AIRMIX 08-120

Страница 1: ...assembly and start up please read and clearly understand all the documents relating to this equipment professional use only THE PICTURES AND DRAWINGS ARE NON CONTRACTUAL WE RESERVE THE RIGHT TO MAKE CHANGES WITHOUT PRIOR NOTICE KREMLIN REXSON l 150 avenue de Stalingrad 93 245 STAINS CEDEX France 33 0 1 49 40 25 25 Fax 33 0 1 48 26 07 16 www kremlin rexson com ...

Страница 2: ...alve 16 If cylinder 2 remains attached to the suction valve unscrew the whole Then hold cylinder 2 by inserting a rod into the cylinder holes designed for this purpose The ball 17 is secured on the valve 16 by means of a circlips 18 Clean the parts Reinstall suction valve 16 and seal 19 Replace them if necessary CYLINDER In order to make easier the disassembly a hole is drilled in the cylinder 2 a...

Страница 3: ...1 10 3 à 8 mm 12 REVERSING BLOCK REFER TO DOC 573 045 050 OR DOC 573 046 050 Guards air motor cover coupling shields housings have been designed for safe use of the equipment The manufacturer will not be held responsible for bodily injury or failure and or damage to property due to removal or partial removal of the guards Disassemble cover 32 by removing screws CHc 33 Dissociate female yoke 12 fro...

Страница 4: ...22 19 18 17 16 15 23 A 2 A 1 A 1 A 1 A 1 A 1 C 1 A 2 A 1 A 2 A 1 A 2 A 2 Index Instruction Description Part number A 1 PTFE grease TECHNILUB grease 10 ml 560 440 101 A 2 Anti seize grease Grease box 450 g 0 99 lb 560 420 005 C 1 Medium strength Aneorobic Pipe sealant Loctite 577 554 180 015 ...