Kremlin-Rexson AIRLESS FLOWMAX 40.130 F2 Скачать руководство пользователя страница 6

KREMLIN REXSON

- 5 -

N° : 578.156.110-UK-1202

UPPER TIGHTNESS SEAL (27)

Disassembly

Unscrew the 8 screws (26)

Separate the fluid sub-assembly (A) from the suction
sub-assembly (B)

Remove the upper ring (35).

Remove the GT seal (27) by pulling the exhaust
flange (20) downwards.

Remove the o-ring seals (8 & 24) which are on the
suction flange.

Assembly

Place the GT-seal (27) in the exhaust flange (20)

after having lubricated it.

Comply with the GT seal (27) installation order.

DETAIL DRAWING

Place the upper part of the piston (22) on the cone shapped tool (refer to

above drawing).

Grease the cone shapped tool.

Slide the piston-cone shapped tool into the exhaust flange (20), from
downwards to upwards.

Slide the GT seal on the whole (the tool prevents from damaging the seal
when assembling the piston).

Remove the tool when it is above the flange (20).

Install the upper ring (35).

Change the seal (8) and tighten the 8 screws (26)

Couple the fluid sub-assembly (B) with the suction sub-assembly (A).

BELLOWS

This operation must be done after the separation of the lower part from the upper part of the fluid
section and after the dismounting of the upper thightness seal.

In the work table, prepare assembly, which consists of fluid section piston-exhaust flange while
following the procedure of the upper thightness seal (27).

Disassembly

Remove the bearing (3) from the cylinder (2).

Separate the suction bearing (3) from the motor by removing the screws (9).

Slide, then put aside the bellows-skirt-flange assembly.

Remove the bellows flange (4) to take off the upper part of the bellows.

Dismount the skirt (6).

27

22

35

20

Содержание AIRLESS FLOWMAX 40.130 F2

Страница 1: ...embly and start up please read and clearly understand all the documents relating to this equipment professional use only THE PICTURES AND DRAWINGS ARE NON CONTRACTUAL WE RESERVE THE RIGHT TO MAKE CHANGES WITHOUT PRIOR NOTICE KREMLIN REXSON l 150 avenue de Stalingrad 93 245 STAINS CEDEX France 33 0 1 49 40 25 25 Fax 33 0 1 48 26 07 16 www kremlin rexson com ...

Страница 2: ...not be held responsible for bodily injury or failure and or damage to property due to removal or partial removal of the guards To remove a component of the pump Disassemble all the accessories of the pump rods filter if it necessary Put aside the pump if it is necessary the pump is fitted with an hoisting ring Before removing the B sub assembly or the A sub assembly you must remove the connecting ...

Страница 3: ... valve unscrew both parts then hold cylinder 21 by inserting a rod into the cylinder holes designed for this purpose The ball 32 is secured on the valve by means of a circlips 33 Clean the parts with the appropriate cleaning solvent Assembly Reinstall the ball 32 and the circlips 33 on the suction valve body 31 Change the seal 13 Lubricate it Lubricate the threading of the valve body Reinstall val...

Страница 4: ... cylinder 21 You can see the fluid section piston 22 You must place the piston downwards install an air pressure from 0 2 to 0 5 bar from 2 9 to 7 2 psi on the air motor to make the piston 22 get down When the piston is at its lower point close the air inlet valve to prevent the piston from getting up Remove the 3 nuts 11 the washers 12 Pull the suction flange 1 downwards you can see the skirt 6 N...

Страница 5: ...assembly Screw the motor rod into the fluid section Apply a light coating of glue to the pump piston threading Loctite 577 Pull the skirt 6 downwards then screw it on the fluid section piston 22 tool 41 mm 1 6 wrench Reinstall the tie rod 7 if you removed it Reinstall the suction flange 1 Tighten the 3 screws 9 Place the 3 washers and tighten the nuts 11 Reinstall the lower part of the pump cylind...

Страница 6: ...T seal on the whole the tool prevents from damaging the seal when assembling the piston Remove the tool when it is above the flange 20 Install the upper ring 35 Change the seal 8 and tighten the 8 screws 26 Couple the fluid sub assembly B with the suction sub assembly A BELLOWS This operation must be done after the separation of the lower part from the upper part of the fluid section and after the...

Страница 7: ...4 grease type A1 Insert the assembly in the bearing 3 When installing the bellows push it into skirt 6 firmly Install the upper bellows flange 14 Slide the bellows skirt flange assembly along the air motor rod Orientate it and tighten it on the air motor base by means of the 3 screws 9 Nota To make easier the assembly you can remove one of the 3 pump tie rods 7 Couple the fluid sub assembly B with...

Страница 8: ...amage to property due to removal or partial removal of the guards Disassemble the air motor cover 6 by removing the nut 4 Dissociate the female yoke 27 from the reversing block lever 9 Dismount the reversing block by removing the screws 28 Reinstall the new reversing block in the reverse order of the disassembly sequence CAUTION the number of spirals must equally be distributed on each fastening p...

Страница 9: ...aging the seals Install new parts if it is necessary DEGREES OF WEAR The wetted parts in contact with the material are subject to wear with time It depends of course on the rates and duration of pump operating also on the material handled Under normal operating and servicing conditions with standard filled material not including foreign matters or chemically aggressive the average working life can...

Страница 10: ...Description Part number A 1 PTFE grease TECHNILUB grease 10 ml 560 440 101 A 2 Graphite grease Graphite grease box 1 kg 2 204 lb 560 420 005 C 1 Medium strength Aneorobic Pipe sealant Loctite 577 C 2 Low strength Aneorobic Adhesive Loctite 222 C 2 C 1 40M 22 6 8 27 A 1 A 1 1 35 20 ...