Attaching the fluid needle
Fig. 15: Attaching the fluid needle
1.
CAUTION!
Risk of injury due to fluid needles!
Hook a new fluid needle ( Fig. 15/2) into the control piston ( Fig. 15/3).
2.
Ensure that the needle stroke adjustment ( Fig. 15/4) (optionally) is relaxed. If necessary,
release the pressure by turning anti-clockwise.
3.
Fig. 16: Attaching the fluid needle
4.
Unscrew the screw ( Fig. 16/2) from the control piston ( Fig. 16/6) and screw it into the main
element again ( Fig. 16/7).
5.
Make sure that the seal ( Fig. 16/4) is seated properly.
6.
Press in the pressure spring ( Fig. 16/3) with the locking part ( Fig. 16/5).
7.
Hook the locking part ( Fig. 16/5) into the screws ( Fig. 16/1).
8.
Tighten the screws ( Fig. 161) evenly.
Operating instructions
T-Dok-449-GB-Rev.7
[email protected], www.krautzberger.com
GB–36