8.4 Changing the material nozzle and the air nozzle
Removing the nozzles
Fig. 12: Removing the nozzles
1.
2.
Remove the air nozzle ( Fig. 12/3).
3.
Unscrew the fluid nozzle ( Fig. 12/2) with a flat spanner.
Always change the fluid nozzle and needle together (
Attaching the nozzles
1.
The air distributor ring ( Fig. 12/1) is only required for flat jet nozzles. When fitting the
automatic spray gun with round or flat jet nozzles, the air distributor ring ( Fig. 12/1) is
not mounted but it is included in the scope of delivery.
If necessary, make sure that the air distributor ring ( Fig. 12/1) is positioned correctly.
2.
Screw on the fluid nozzle ( Fig. 12/2) with a flat spanner.
3.
Attach the air nozzle ( Fig. 12/3) and tighten it with the cap nut ( Fig. 12/4).
Automatic spray gun RA 5
ENGLISH
200-0319
■
200-0321
■
200-0323
■
200-0324
GB–33