7.4 Changing the fluid needle
Removing the fluid needle
1.
Chapter 7.2 ‘Cleaning spray guns’ on page 25
Fig. 11: Removing the fluid needle
2.
WARNING!
The closing piece ( Fig. 11/1) is under spring force!
Carefully unscrew the entire closing piece ( Fig. 11/1).
3.
Remove the spring ( Fig. 11/2).
4.
Take the entire valve shaft ( Fig. 11/3) out of the main element ( Fig. 11/4).
Fig. 12: Removing the fluid needle
5.
Loosen the nut ( Fig. 12/1) of the valve shaft pipe ( Fig. 12/4).
6.
Remove the spring ( Fig. 12/2) and fluid needle ( Fig. 12/3) from the valve shaft pipe (
Fig. 12/4).
Fig. 13: Check the seals
7.
Check the seals ( Fig. 13/1 to 6) for damage, replace if necessary.