6.6 Checking connections
1.
Disconnect spray fluid supply.
Fig. 5: Checking closures
2.
Completely open the round jet controller ( Fig. 5/2, if present) and the flat jet controller (
Fig. 5/1) . To do this, turn the regulator anti-clockwise up to the stop.
3.
Open the adjusting nut ( Fig. 5/3) of the needle stroke adjustment maximum 5.5 mm (
Fig. 5). To do so, turn the adjusting nut ( Fig. 5/3) counter-clockwise.
One turn of the needle stroke adjustment moves the needle by 1 mm and corresponds
to 18 positions.
ð
No air may escape from the automatic spray gun.
4.
Open the control air.
ð
The needle of the fluid nozzle must push itself back and air must escape from the air
nozzle.
5.
Close the control air again.
6.
Establish fluid supply.
ð
No spray fluid may escape from the automatic spray gun.
Operating instructions
T-Dok-040-GB-Rev.5
[email protected], www.krautzberger.com
GB–20