other parts and accessories which are not
mentioned in the manual otherwise injuries
may be caused!
Special attention to voltage: Before
connecting the power tool, please make sure
the rated voltage on the tool matches the
power supply, otherwise the power tool may
be damaged and cause injuries.
Don’t wipe plastic parts with solvents:
Solvents such as gasoline, thinner, alcohol
and similar kind of chemical material
are not allowed to use. Water or soap is
recommended!
Damage to lungs if an effective dust mask
is not worn.
Damage to hearing if effective hearing
protection is not worn.
Damages to health resulting from vibrations
if the power tool is being used over longer
period of time or not adequately managed
and properly maintained.
Even when the power tool is used as prescribed it
is not possible to eliminate all residual risk factors.
The following hazards may arise in connection with
the power tool’s construction and design:
Residual risks
The declared vibration total value has been
measured in accordance with a standard test
method and may be used for comparing one tool
with another.
T
he declared vibration total value may also be
used in a preliminary assessment of exposure.
There is the need to identify safety measures
to protect the operator that are based on an
estimation of exposure in the actual conditions
of use (taking account of all parts of the operating
cycle such as the times when the tool is switched
off and when it is running idle in addition to the
trigger time).
SAVE THESE INSTRUCTIONS
WARNING:
M
isuse or failure to follow the safety rules stated in this
instruction manual may cause serious personal injury.
WARNING:
Τhe vibration emission during actual use of the power tool
can differ from the declared total value depending on the
ways in which the tool is used.
WARNING:
Τhis power tool produces an electromagnetic field during
operation. This field may under some circumstances
interfere with active or passive medical implants. To
reduce the risk of serious or fatal injury, we recommend
persons with medical implants to consult their physician
and the medical implant manufacturer before operating
this machine.
4. Functional description
and specifications
WARNING:
I
f the replacement of the supply cord is necessary, this has
to be done by a professional in order to avoid a safety
hazard.
Intended use
The demolition hammer is designed to break,
scale, drive concrete or similar material. For
example for the installation of tubes, cables,
washroom facillities of draining and other civil
engineering works.
Power supply
Power input
No-load speed
Impact energy
Piston diameter
Point chisel
Flat chisel
Weight
2
30 V ~ 50 Hz
1800 W
2000 min
-1
65 J
46 mm
Hexagonal
Hexagonal
18.5 kg
Tool
9991