13
Trouble-Shooting
If you have followed the instructions carefully and your faucet still does not work properly, take the following corrective steps:
Leakage under the handle
Locking nut has come loose
Remove cap. Loosen set screw with a hex
wrench. Remove the handle and unscrew
cartridge cover by hand. Tighten locking
nut with an adjustable wrench.
Leaking between spray head
and hose.
Spray head may be loose, or washer
may not be seated correctly in hose
Tighten spray head by hand until snug.
Make sure washer is seated correctly.
Care & Maintenance
To keep the product clean & shining, follow the steps below:
1.
Rinse with clean water & dry with a soft cloth
2.
Do not clean with soaps, acid, polish, abrasives or harsh cleaners
3.
Do not use cloth with a coarse surface
4.
Unscrew the aerator and clean when necessary
This installation manual is subject to change without further notice.
Water will not shut off completely
Cartridge may be defective
Remove cap. Loosen set screw with a hex
wrench. Remove the handle and unscrew
cartridge cover by hand. Unscrew the
locking nut with an adjustable wrench.
Remove ceramic disc cartridge. Check for
cracks.
ACID
PROBLEM
CAUSE
ACTION
The water pressure is low.
EZ-Connect (21) may be clogged with
debris
Remove EZ-Connect from supply hose and
spray hose. Soak quick connect in vinegar
& warm water 50/50 solution for 5 - 10
minutes.
Hose does not retract
Weight may be installed incorrectly
Readjust weight on hose.