Trouble - Shooting
If you have followed the instructions carefully and your faucet still does not work
properly, take the following corrective steps:
P R O B L E M
C A U S E
A C T I O N
Leakage under the
handle
Locking nut (4) has
come loose
Remove handle
index button (1a).
Loosen set screw
(1b) with hex wrench
(9). Remove metal
handle (2). Unscrew
cartridge cover (3) (by
hand only). Tighten
locking nut (4) with an
adjustable wrench
Aerator drips or has
inconsistent water flow
pattern
Aerator (9) may be dirty
or not seated properly
Unscrew aerator (9)
with aerator key (10)
and clean out debris
Water will not shut off
completely
Cartridge may need to
be adjusted or replaced
Remove handle index
button (1a). Loosen
set screw (1b) with hex
wrench (9). Remove
metal handle (2).
Unscrew cartridge
cover (3) (by hand
only). Unscrew the
locking nut (4) with
an adjustable wrench.
Remove ceramic disc
cartridge (5). Check for
cracks
Drain is leaking
Washers may be
compromised or
installed incorrectly
Check washers to make
sure they are installed
correctly and not
cracked
Care & Maintenance
*To keep the product clean & shining, follow the steps below:
1.
Rinse with clean water & dry with a soft cloth
2.
Do not clean with soaps, acid, polish, abrasives, or harsh cleaners
3.
Do not use cloth with a coarse surface
4.
Unscrew the aerator and clean when necessary
*This installation manual is subject to change without further notice.
1
10
279
10 31/32”
Minimum distanc
e 90mm
Less than 90mm
Cold Water
32 3/32”
Ø35~Ø38
1
2
3
10
9
11
12
13
Hexagon Nut
Hot
Water
Cold
Water
2 3
1
4
5
7
6
8
4
5
6
7
8
Ø1 3/8”~
Ø1 1/2”
815
194
7 5/8”
Ø1 3/8~Ø1 1/2”
30˚
10
11
Close
Open
Left
Hot Water
Push
25˚
90˚
12
13
8
7
Ø35~Ø38
M
ax35
217
8 17/32”
M
ax1 3/8”
9
11
12
13
2
3
4
5
6
7
8