46
Inspections
Accident prevention
The machine must be inspected according to the “Guidelines for Liquid Spray De-
vices” at least once every 12 months by a qualified person, to ensure that continu-
ed safe operation is guarateed.
The results of the inspection are to be recorded in writing. (see pages 48-49)
General rules
The machine is designed for accidents to be impossible if used correctly.
The operator is to be notified of the risk of injury from hot machine parts and the
high pressure water jet. The “Guidelines for Liquid Spray Devices” must be com-
plied with. (see pages 16 - 17).
Check the oil level at the oil dip stick prior to each use (see also page 11).
(Ensure horizontal position!)
Oil change:
The first oil change should be carried out
after approximately 50 operating hours,
then every year or after 1000 operating
hours. If the oil turns grey or white, you
must change the oil of your high pressure
pump in any case.
Place the device over a collection resevoir
and open the oil discharge screw at the
bottom.
Ensure a horizontal position to drain the oil
completely. The oil is to be caught in the
reservoir and disposed of in an approved
manner.
New oil: 0,4 l
Motor oil: Castrol 10 W-60 SAE halfsynthetic oil
Oil discharge screw
Содержание quadro 11/140 TST
Страница 22: ...22 Complete Assembly...
Страница 24: ...24 Water inlet and brake...
Страница 26: ...26 Pump motor...
Страница 28: ...28 Pump motor...
Страница 30: ...30 Pump...
Страница 32: ...32 Pump...
Страница 34: ...34 Unloader valve and pressure switch...
Страница 36: ...36 Valve housing...
Страница 38: ...38 Valve housing...
Страница 40: ...40 Hose drum...
Страница 51: ...51 Notes...