Kramer Electronics Ltd.
VS-88UT
– Connecting VS-88UT and VS-84UT
14
Figure 6: Connecting to the
VS-84UT
Rear Panel
Connect the Controller Ports
To connect the VS-88UT/VS-84UT Controller as illustrated in the example in
1. Connect an IR sensor to IR IN 1 3.5mm mini jack (1 to 2)
.
For example, point an IR remote controller to the IR sensor to control a device that is
connected to a controller port.
2. Connect the IR OUT 2-pin terminal block connector (1 to 4)
to an IR emitter and
attach the emitter to a controlled device (for example, a display).
3. Connect the GPI/O 2-pin terminal block connector (1 to 4)
to an input/output device
(for example, a motion detector).
4. Connect the RELAY 2-pin terminal block connector (1 to 8)
to a relay port (for
example, a controlled screen).
5. Connect the RS-232 3-pin terminal block connector (1 to 4)
to a serially controlled
device (for example, a projector).
6. Connect the RS-485 3-pin terminal block connector
to a controlled system (for
example, a lighting system).
7. Connect the K-NET 4-pin terminal block connector
to a room controller (for example,
the Kramer
RC-63DLN
).
The room controller is powered via the 12V pin.