Kramer Electronics Ltd.
VS-6464DN-EM
– Upgrading VS-6464DN-EM and Input / Output Card Firmware
53
Upgrading VS-6464DN-EM and
Input / Output Card Firmware
The
VS-6464DN-EM
enables upgrading both the device’s firmware and that of the
VGAA-
IN8/OUT8-F64
card. Upgrading the firmware of the remaining input / output cards can only be
done by authorized service personnel.
The device and card firmware can be upgraded using:
•
K-Upload via RS-232, USB (VCOM), or Ethernet (see
•
Kramer Network via Ethernet (see
Upgrading Firmware Using Kramer Network
Upgrading Firmware Using K-Upload
The
VS-6464DN-EM
enables
upgrading device and card firmware via RS-232, USB (VCOM)
or Ethernet using the K-Upload software application, available at
www.kramerav.com/product/VS-6464DN-EM
. For instructions on upgrading the firmware
using K-Upload, see the
K-Upload User Manual
.
For information on connecting to the
VS-6464DN-EM
via RS-232, USB (VCOM), or Ethernet,
Connecting to the VS-6464DN-EM via RS-232
, or
Connecting to the VS-6464DN-EM via
, respectively.
Firmware may be available for any of the following components:
The firmware files for each component have different suffixes to help with identification.
•
VS-6464DN-EM
Control Module
– Control module firmware files end with
_0
, for
example:
linux163264_[APP_X_xx.xx_xxxx]_0
•
VS-6464DN-EM
Test Module
– Test module firmware files end with _
200
, for example:
64testCard_[OUT8_47_xx.xx_xxxx]_200
•
VS-6464DN-EM
Keypad
– Keypad firmware files end with _
201
, for example:
VS-163264Keypad_[APP_X_xx.xx_xxxx]_201
•
VGAA-IN8/OUT8-F64
Card
– The suffix of card firmware files must be modified before
use. Input and output card firmware files all end with
_N
, for example:
VGA VGAA_[OUT8_16&18_xx.xx_xxxx]_N
This suffix must be changed according to the slot number in which the card is installed
(1-
16). For example if the card is installed in slot 7, the firmware file’s suffix must be
changed to
_7
:
VGA VGAA_[OUT8_16&18_xx.xx_xxxx]_7