– Managing IO Gateway Settings
42
Setting GPI/O Parameters
Use the GPIO setting tab to configure the following GPI/O ports:
▪
Configuring the Digital Input Trigger Type
▪
Configuring the Digital Output Trigger Type
▪
Configuring the Analog Input Trigger Type
GPI/O ports can be incorporated into automation only when they are set as inputs (see
Configuring the Digital Input Trigger Type
Digital Input trigger mode reads the digital input of an external sensor device that is connected
to the GPIO port and can detect a:
•
High state voltage
– when the connected sensor passes the maximum threshold from the
low state.
•
Low State voltage
– when the connected sensor passes the minimum threshold from the
high state.
The minimum and maximum threshold levels are defined in the GPIO web page.
To configure the digital input trigger type:
1. In the Navigation pane, click
IO Gateway
. The IO Gateway page appears (see
2. Click
GPIO
. The GPIO tab appears.
Figure 43: IO Gateway Page
– GPIO Tab