22
VS-41HDCP - Kramer Protocol
10.2
Kramer Protocol 3000
This RS-232/RS-485 communication protocol lets you control the machine from any
standard terminal software (for example, Windows
®
HyperTerminal) with default
settings of 115200 baud data rate, no parity, 8 data bits, and 1 stop bit.
10.2.1
Protocol 3000 Syntax
Host message format:
Start
Address (optional)
Body
Delimiter
#
Destination_id@
message
CR
Simple command (commands string with only one command without addressing):
start
body
delimiter
#
Command SP Parameter_1,Parameter_2,…
CR
Commands string (formal syntax with commands concatenation and addressing):
#
Address
@ Command_1
Parameter1_1,Parameter1_2,…
|
Command_2
Parameter2_1,Parameter2_2,…
|
Command_3 Parameter3_1,Parameter3_2,…
|…
CR
Device message format:
Start
Address (optional)
Body
Delimiter
~
Sender_id@
message
CR LF
Device long response (
Echoing command
):
Start
Address
(optional)
Body
Delimiter
~
Sender_id@
command
SP
[param1 ,param2 …]
result
CR LF
CR
= Carriage return (ASCII 13 = 0x0D)
LF
= Line feed (ASCII 10 = 0x0A)
SP