VS-211HA - Operating the VS-211HA

 

 

To set Automatic/Priority mode: 

 

Slide AUTO/MANUAL DIP 1 up to AUTO and LAST/PRIORITY DIP 2  down 

to PRIORITY 

In Automatic/Last mode, the last connected input is sent to the output 

 

If Inputs 1 and 2 are active when the 

VS-211HA

 is powered on, Input 1 is 

sent to the output (as the priority input) 

 

If Input 2 is disconnected, Input 1 is still sent to the output 

 

If Input 2 is reconnected, Input 2 is sent to the output 

For example, a salesman connected to Input 1 displays a presentation on the AV system 
of a boardroom. A second salesman arrives, connects to Input 2 and continues with 
his/her presentation. 

To set Automatic/Last Connected mode: 

 

Slide AUTO/MANUAL DIP 1 up to AUTO and LAST/PRIORITY DIP 2  up to 

LAST 

5.3 

Using the Override Mode 

Override mode is used while the 

VS-211HA

 is in either Priority or Last connected 

automatic mode. Pressing either of the contact closure switches: 

 

Forces the chosen input, if it is active, to be sent to the output  

 

If the forced signal is inactive for 10 seconds, the 

VS-211HA

 returns to auto 

mode 

 

If the forced signal is lost, the 

VS-211HA

 reverts to its selected mode 

For example, a sales manager, connected to Input 1, displays a presentation on the AV 
system of a boardroom. A salesman arrives and wants to connect to Input 2 without 
interrupting the manager. They press the Input 1 contact closure switch to allow Input 2 to 
connect without interrupting Input 1. 

Содержание VS-211HA

Страница 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL VS 211HA Automatic HDMI Standby Switcher P N 2900 300378 Rev 2...

Страница 2: ......

Страница 3: ...A Automatic HDMI Standby Switcher 5 4 Connecting the VS 211HA 6 4 1 Connecting the REMOTE Terminal Block Connector 7 5 Operating the VS 211HA 8 5 1 Using the Manual Mode 8 5 2 Using the Automatic Mode...

Страница 4: ...by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Produc...

Страница 5: ...terference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tight bundles or roll the slack into tigh...

Страница 6: ...ected and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment recycling and reco...

Страница 7: ...her automatically switches to the newly introduced input In addition the VS 211HA features A maximum data rate of up to 6 75Gbps 2 25Gbps per graphic channel HDTV compatibility HDCP and HDMI complianc...

Страница 8: ...iving power 6 IN 1 AUDIO INPUT 3 5mm Mini Jack Connector Connects to unbalanced stereo audio source 1 Audio is independent of video and switching is audio follows video 7 IN 2 AUDIO INPUT 3 5mm Mini J...

Страница 9: ...lanced stereo audio source for example stereo player 1 to the 3 5mm mini jack connector AUDIO IN 1 4 Connect an unbalanced stereo audio source for example stereo player 2 to the 3 5mm mini jack connec...

Страница 10: ...e REMOTE input terminal block connector pins to a contact closure switch see Figure 3 To select IN 1 Momentarily connect REMOTE IN1 to PIN G ground To select IN 2 Momentarily connect REMOTE IN2 to PIN...

Страница 11: ...Select the required port manually by pressing the switches connected to the terminal block 5 2 Using the Automatic Mode Automatic mode uses automatic signal detection to determine the device s behavio...

Страница 12: ...is her presentation To set Automatic Last Connected mode Slide AUTO MANUAL DIP 1 up to AUTO and LAST PRIORITY DIP 2 up to LAST 5 3 Using the Override Mode Override mode is used while the VS 211HA is i...

Страница 13: ...CONTROLS Contact closure on a 3 pin terminal block 2 priority DIP switches INDICATORS ON and active input LEDs POWER CONSUMPTION 5V DC 120mA without load 350mA fully loaded OPERATING TEMPERATURE 0 to...

Страница 14: ......

Страница 15: ...sit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com P N 2900 300378 Rev 2 SAFETY...

Отзывы: