Kramer VS-1604 Скачать руководство пользователя страница 21

 

 

 

KRAMER ELECTRONICS, LTD. 

19 

LIMITED WARRANTY 

Kramer  Electronics  (hereafter  Kramer)  warrants  this  product  to  be  free  from  defects  in  material  and 

workmanship under the following terms. 

HOW LONG IS THE WARRANTY 

Labor and parts are warranted for three years from the date of the first customer purchase. 

 

WHO IS PROTECTED 

Only the first purchase customer may enforce this warranty. 

 

WHAT IS COVERED AND WHAT IS NOT COVERED 

Except  as  below,  this  warranty  covers  all  defects  in  material  or  workmanship  in  this  product.  The 

following are not covered by the warranty: 

1.  Any product which is not distributed by Kramer or which is not purchased from an authorized 

Kramer dealer. If you are uncertain as to whether a dealer is authorized, please contact Kramer at 

one of the agents listed in the web site 

www.kramerelectronics.com

2.  Any product, on which the serial number has been defaced, modified or removed. 
3.  Damage, deterioration or malfunction resulting from: 

a) 

Accident, misuse, abuse, neglect, fire, water, lightning or other acts of nature. 

b) 

Unauthorized product modification, or failure to follow instructions supplied with the 

product. 

c) 

Repair or attempted repair by anyone not authorized by Kramer. 

d) 

Any shipment of the product (claims must be presented to the carrier). 

e) 

Removal or installation of the product. 

f) 

Any other cause, which does not relate to a product defect. 

g) 

Cartons,  equipment  enclosures,  cables  or  accessories  used  in  conjunction  with  the 

product. 

 

WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR 

We will pay labor and material expenses for covered items. We will not pay for the following: 

1.  Removal or installations charges. 
2.  Costs  of  initial  technical  adjustments  (set-up),  including  adjustment  of  user  controls  or 

programming. These costs are the responsibility of the Kramer dealer from whom the product was 

purchased. 

3.  Shipping charges. 

 

HOW YOU CAN GET WARRANTY SERVICE 

1.  To  obtain  service  on  you  product,  you  must  take  or  ship  it  prepaid  to  any  authorized  Kramer 

service center. 

2.  Whenever warranty service is required, the original dated invoice (or a copy) must be presented 

as proof of warranty coverage, and should be included in any shipment of the product. Please also 

include in any mailing a contact name, company, address, and a description of the problem(s). 

3.  For the name of the nearest Kramer authorized service center, consult your authorized dealer. 

LIMITATION OF IMPLIED WARRANTIES 

Содержание VS-1604

Страница 1: ...KRAMER ELECTRONICS Ltd USER MANUAL MATRIX SWITCHER Model VS 1604 IMPORTANT Before proceeding please read paragraph entitled Unpacking and Contents...

Страница 2: ...7 Using the Audio Follow Video Mode 7 9 2 8 Storing a Configuration 7 9 2 9 Recalling a Configuration 8 9 2 10 Deleting a Setup 8 9 2 11 Using the take function 8 9 2 12 Resetting the machine 8 9 2 1...

Страница 3: ...ral video sources as in live broadcast to ensure clean undisturbed picture transitions The switched sources should be genlocked Matrices and switchers may sometimes be RS 232 or RS 485 422 controlled...

Страница 4: ...section doesn t apply to you you don t have to spend your time reading it UNPACKING AND CONTENTS The items contained in your Kramer accessory package are listed below Please save the original box and...

Страница 5: ...411 has two inputs video and audio each splitting to 5 outputs The user may select 2 x 1 5 or 1 10 operation via front panel control switches Several VM 1411 units may be chained through the looping i...

Страница 6: ...t signal is switched to 3 VIDEO OUTPUT STATUS Displays the selected video input switched to the output above 4 AUDIO OUTPUT STATUS Displays the selected audio input switched to the output above 5 POWE...

Страница 7: ...s in the non volatile memory For example Press STO followed by INPUT 4 button to store Setup 4 in the non volatile memory NOTE To delete a setup from the memory press the STO and RCL buttons simultane...

Страница 8: ...gnal connections that use more than one cable interconnecting between devices should be of equal length Example cables between a camera and the machine should be equal in length CONNECTING TO AUDIO DE...

Страница 9: ...link as well which means that the audio configuration will be modified for AFV operation Press the TAKE button to confirm the modification 9 2 8 Storing a Configuration To store a configuration press...

Страница 10: ...ition as shown in Table 3 and Figure 2 Master Slave Dipswitches configure the matrix switcher for operation in a multiple switcher configuration In the case of interconnection between more than two RS...

Страница 11: ...ing the PC to the RS 485 terminal block connector Bear in mind that serial communication between matrix switchers is always via RS 485 see example in Figure 5 The RS 232 port is either a DB 9 9 pin po...

Страница 12: ...o source 1 to input 1 video source 2 to input 2 etc at the VS 1604 at address 1 Connect video sources 17 32 to inputs 1 16 of the VS 1604 machine at address 2 similarly video sources 33 48 should be c...

Страница 13: ...1604 matrices where some of the machines are connected for simple parallel operation and some of the machines form a large composite matrix of 48x4 Figure 5 Multiple Matrices setup Parallel Operation...

Страница 14: ...e receptacle is active outputting the proper mains voltage 3 If there is still no power check the fuse Remove power cord from the AC outlet and from the machine and then using a flat screwdriver remov...

Страница 15: ...me until the ground loop reappears Disconnect the affected cable and replace or insert an isolation transformer in the signal path Audio Signal Problem Remedy No audio at the output device regardless...

Страница 16: ...Switching Malfunctions Problem Remedy The switcher succeeds in switching a number of sources then fails to switch one Malfunction in the particular source or cable assembly NOTE The most common failu...

Страница 17: ...number which is to be switched Similarly if switching is done via the machine s front panel then these bits are set with the INPUT NUMBER which was switched For other operations these bits are define...

Страница 18: ...T Set as SETUP 0 15 Equal to output number whose status is req 4 3 7 VIS SOURCE 0 No VIS immediate 1 Input 1 2 5 8 BREAKAWAY SETTING 0 0 audio follow video 1 audio breakaway 2 10 REQUEST VIS SETTING S...

Страница 19: ...r the definitions in instructions 7 and 8 respectively For example if the present status of machine number 5 is breakaway setting then the reply to the HEX code 0B 80 80 85 would be 4B 80 81 85 NOTE 6...

Страница 20: ...PUT and OUTPUT If the request for identification is sent with the INPUT set as 3 or 4 the appropriate machine will send its software version number Again the reply would be the decimal value of the IN...

Страница 21: ...upplied with the product c Repair or attempted repair by anyone not authorized by Kramer d Any shipment of the product claims must be presented to the carrier e Removal or installation of the product...

Страница 22: ...ecific legal rights and you may also have other rights which vary from place to place NOTE All products returned to Kramer for service must have prior approval This may be obtained from your dealer NO...

Страница 23: ...m P N 2900 002004 REV 2 For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com Updates to this user manual may be found at http www k...

Отзывы: